19
The maximum load the load
cell can withstand is 250 lbs
(113 kg). Exceeding this limit
can cause permanent damage
to the meter. The “Excessive Force” warning message
appears when 210 lbs (95 kg) or more is applied to the
load cell.
Start Over
Excessive Force
This error message indicates
that the meter missed a depth
reading. This can be caused
by a momentary, but rapid,
insertion of the probe into the
soil or by an object such as a foot or a knee suddenly com-
ing into the field of view of the sonic depth sensor. You
have the option of saving this profile anyway by pressing
the
Review
button. This will bring up the Reading Com-
plete screen (see p. 9). When reviewing the profile, you’ll
see a Profile Information Screen with an error message on
the lower line. Data records
saved after a depth error was
detected will have cone in-
dexes of 0 PSI at all missed
depths
0010 PSI 00 IN
!! Depth Error !!
!! Depth Error !!
Hit RVW to Save
Indicates the batteries need to
be changed. The battery com-
partment is located beneath the
face of the meter.
Low Battery
Summary of Contents for SC 900
Page 1: ...SC 900 Soil Compaction Meter PRODUCT MANUAL ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 R 12 13 ...