WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire
®
Air Purifying System out of the plenum
. Avoid touching the glass portion of the lamp with your hands.
Model
Volts Amps Hz Watts Lamp Intensity at
1 meter
Recommended
Max. Sq. Feet
Weight
Width
(Inches)
Height
(Inches)
Depth
(Inches)
UV-1500C
120
1.3
60
130
37µW/cm
2
1500
15.5 lbs
18
23-
3
⁄
4
6-
5
⁄
16
INDICATION FOR USE
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or
condition nor for use in the mitigation, treatment, or prevention of any disease or condition.
GENERAL INFORMATION
WARNING:
This product is designed for indoor installation only.
The UV-1500C is designed as a multipurpose room air purification system. The unit can be placed in a room
sitting on the floor, it can be mounted on the wall to maximize floor space, or it can be mounted into a
suspension (drop) ceiling.
FEATURES
The UV-1500C is equipped with a speed control to allow the user to adjust the airflow through the unit
1.
from 35 cfm to 100 cfm.
The UV-1500C has a safety shut off switch that disconnects power to the fan and the lamp if the front
2.
access door is opened.
The UV-1500C is equipped with a circuit board to monitor the operation of the UV lamp; it indicates the
3.
operation of the lamp through an LED indicator light mounted on the front access door. The circuit board
indicates good operation of the lamp by a continuous “GREEN” color on the LED light. After 8320
hrs of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous
“YELLOW” color on the LED light and the internal alarm will beep every 15 minutes. After 9000 hrs of
lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED”
color on the LED light and the internal alarm will beep every 5 minutes. The board also checks if the UV
lamp is burned out. The circuit board will indicate this by a continuous “RED” color on the LED and the
internal alarm will beep every 5 minutes.
UV-1500C CHECK OUT PROCEDURE
Plug the power cord into a standard 120-volt wall receptacle.
1.
Turn the speed control knob clockwise to turn the unit on. After the fan has started, the LED light will
2.
show a continuous “GREEN” color indicating proper unit operation.
Once you have determined that the unit is functioning properly, turn unit off and unplug.
3.
Continue to next section for mounting options.
4.