page 2
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum
. Avoid touching the glass portion of the lamp with your hands.
UV-500C SET UP PROCEDURE
Remove the lamp from the top carton pad.
1.
Remove the lamp connector from the bagged parts provided.
2.
Remove the UV-500C from its protective plastic bag.
3.
WARNING:
DO NOT PLUG INTO WALL OUTLET!
Connect the UV lamp to the lamp connector knob. (See Figure 1)
4.
Clean the lamp with the alcohol swab provided. (See Figure 2)
5.
NOTE:
Dirt and fingerprints will reduce lamp output
and effectiveness.
Open the lamp access door on the back of the unit.
6.
Model Volts Amps Hz Watts
Lamp Intensity
at 1 meter
Recommended
Max. Sq. Feet
Weight
Width
(Inches)
Height
(Inches)
Depth
(Inches)
UV-
500C
120
.4
60
38
15µW/cm
2
500
11 Lbs
12
15
13
Figure 1
Figure 2
INDICATION FOR USE
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or
condition nor for use in the mitigation, treatment, or prevention of any disease or condition.
GENERAL INFORMATION
FEATURES
The UV-500C is equipped with a three speed control to allow the user to adjust the airflow through the
1.
unit from 30 cfm to 70 cfm. Any speed is effective in rooms up to 500 square feet
The UV-500C is equipped with a circuit board to monitor the operation of the UV lamp and the
2.
operation time until the filter or lamp needs to be changed.