www.fieldcontrols.com
Please retain these instructions after installation.
This device
MUST
be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
Installation Date:
Installed By:
Phone:
UV-AIRE
®
AIR PURIFYING SYSTEM
Model: UV-500C
UV-500C Features
8" germicidal UV lamp
10"x10" high-efficiency/carbon filter
Heavy-duty three speed fan
Visual lamp and filter condition
Adjustable fan control
Built in handles for easy portability
Non-skid rubber feet
The high intensity ultraviolet light attacks airborne mold, bacteria, and viruses. The high efficiency filter traps
allergens, dust, and pollen. The carbon filter removes odors and attacks VOCs (volatile organic compounds).
LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE.
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT
INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
SAFETY CONSIDERATIONS
WARNING:
Never expose eyes or skin to UVC light from any source.
• Looking directly at the UVC light may cause permanent eye damage or blindness.
• Never operate the UV-Aire Air Purifying System with the UV lamp access door open.
WARNING:
DO NOT mount this unit outdoors.
• This product is designed for indoor installation only.
WARNING:
To avoid electrical shock hazard, do not operate in wet environment.
ITEMS INCLUDED IN SYSTEM:
1- UV-Aire UV-500C unit
1- Ultra Violet Lamp Individually Boxed
1- Instruction Sheet
4- 10"x 10"x 1" Filters
1- Bagged Parts: containing lamp connector,
alcohol swab and access door screw
*For best results, operate
the UV-500 continuously 24