WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage 

or blindness.Never operate the Trio Air Purifying System out of the ductwork. Avoid touching the glass portion of the lamp with your hands.

Page 4 of 12

P/N 780105101 11/20  Rev B

AIR CYCLES PER DAY

Fan unit on for 10 minutes per hour                  Air cycled(24) ------ times per day

Fan unit on for 15 minutes per hour                  Air cycled(31) ------ times per day

Fan unit on for 20 minutes per hour                  Air cycled(42) ------ times per day

Fan unit on for 30 minutes per hour                  Air cycled(63) ------ times per day

NOTE:

NOTE: In the event, the existing thermostat does not have the capability to operate the air-handler fan unit
independently of a demand for heating or air-conditioning, it is highly recommended to install the Field Controls
Healthy Home System Control Plus (HHSC+) programmable ventilation system (included with -HHS models).

This device is simply wired in parallel with the existing thermostat and can be programmed to turn on the air
handler fan unit for any desired interval. A memory tracks the time the fan unit operates every hour and only
cycles the fan unit that hour if normal requirements for heating and air conditioning have not cycled the fan unit
long enough to meet air purifi cation requirements.

COST OF CONTINUOUS (24) HR PER DAY OPERATION PER MONTH

   Electricity 

cost 

 

 

 

per kilowatt hour                   .06 kw hr.           .08 kw hr.            .10 kw hr.

   TRIO 

(32.25 

kw 

hours)

 

 

 

cost per month                           $1.93                   $2.58                    $3.22

During periods where the fan unit is being operated for the sole purpose of air purifi cation, usually during
the spring and fall season when there is no requirement for heating or cooling, the cost of running a 1/2
horsepower fan unit will add approximately $5.36 per month to the normal operating cost. However, this cost is
easily off set in savings on medication, doctors offi

  ce visits, mechanical maintenance and cleaning of fan units,

refrigeration coils, dirty air ducts and last but not least, less house cleaning.

OPERATION

The Trio Air Purifi cation System installs in the air-inlet side of any heating and airconditioning system up to fi ve tons 
in size. Only operation of the air-handler fan unit is required for air purifi cation and sterilization to take place.

NOTE: 

NOTE: The UVC germicidal lamps are wired to operate continuously. This feature allows the catalyst to burn off 
surface impurities, cleaning and reactivating itself during periods of non-use or no airfl ow. The cost of operation is 
less than .07 cents per day. See operating cost section.

The Trio Air Purifi cation System combines three unique technologies to protect people against indoor air pollutants. 
Photo catalytic technology (PCO) combined with high effi

  ciency electro-statically super charged MERV13 particu-

late fi lter and UVC germicidal light quickly reduces and eliminated toxic gas-phase chemicals, lung damaging dust 
and airborne germs from the living environment.

Many new homes have smart programmable thermostats that allow for automatic operation of the air-handler fan
unit when there is no demand for heating or air conditioning. It is important that the TRIO Air Purifi cation System is
operating at least 20-30 minutes per hour (24) hours per day to remove airborne contaminants from the indoor 
environment.

Individuals that are sensitive to mold spores, dust mites, chemicals or have respiratory problems such as asthma, 
emphysema, and chronic allergies should extend the run time to (40) minutes or more per hour.

AIR CYCLES PER HOUR 

(Based on 3000 sq. ft.)

Fan unit on for 10 minutes per hour Air cycled(1) ------- times per hour

Fan unit on for 15 minutes per hour Air cycled(1.3) ----- times per hour

 Fan unit on for 20 minutes per hour Air cycled(1.75) ---- times per hour

  Fan unit on for 30 minutes per hour Air cycled(2.62) ---- times per hour

Summary of Contents for Healthy Home System Trio-16

Page 1: ...ers only capture particles The TRIO electronic air purifier not only removes particles but also attacks viruses germs and toxic gases This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation treatment or prevention of any disease or condition READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY READ THESE INSTRUCTION...

Page 2: ... If lamp is damaged cracked or broken do not touch lamp or other contents in carton Close carton and return to seller immediately carton Close carton and return to seller immediately In case of accidental exposure to internal contents of lamp wash hands and any other affected In case of accidental exposure to internal contents of lamp wash hands and any other affected skin area with mild detergent...

Page 3: ...ication 1 5 to 3 Ton Drive Air Handler Furnace Max Face Velocity 500 FPM Max Air Flow 1200 CFM UVC Lamp Service 1 year recommended 16 000 hour 2yr lamps efficiency UVC Range 253 7 nanometers nm Germicidal Filter Replacement 6 to 12 months 6 months recommended Model Trio 20 Capacity 1 5 to 4 0 tons Model Trio 20 Trio 20 HHS Power 120V 60 Hz 6 Amps 49 2 Watts Fuse Replace only with AGC 2 fuse Applic...

Page 4: ...cost is easily offset in savings on medication doctors office visits mechanical maintenance and cleaning of fan units refrigeration coils dirty air ducts and last but not least less house cleaning OPERATION The Trio Air Purification System installs in the air inlet side of any heating and airconditioning system up to five tons in size Only operation of the air handler fan unit is required for air ...

Page 5: ...arrow for proper installation The Trio is designed to be installed on indoor HVAC forced air ducted systems Do Not installTrio on the supply air side of HVAC to be installed on indoor HVAC forced air ducted systems Do Not installTrio on the supply air side of HVAC equipment Do Not install outdoors Product is not designed to be exposed to outdoor elements equipment Do Not install outdoors Product i...

Page 6: ...sly 2 Remove the inside module filter from the outer cabinet Take care not to bend or distort the cabinet The ballast is factory set to 120VAC Please confirm the voltage on both ballasts is correct The voltage can be changed in the field to 230VAC by sliding the voltage selector switch in Figure 5 to the 230 volt position The plug must be replaced and wiring must be done to applicable electrical c...

Page 7: ...ided between the outer and inner case 7 Slide the filter into the upstream slot of the cabinet ensuring the correct air flow direction Slide the inner module into the downstream slot of the cabinet The catalytic aluminum substrate should be facing downstream such that the lamps are not exposed to the open duct 8 Replace the door on the unit per the steps listed previously 9 Plug in the power cord ...

Page 8: ...FILTER AND UV LAMP SERVICE TIME Under normal conditions the Filter should be changed out every 180 days Under normal conditions the UV Lamp should be changed out every 365 days Contact your local Field Service Contractor or Distributor for replacement parts Replacement part numbers are provided in parts list section of this manual There are several ways to track the remaining useful life of media ...

Page 9: ...lug the ballast connector back on to the lamp FIGURE 9 FIGURE 10 FIGURE 11 REPLACING THE LAMP Recommended every 12 months of continuous service Recommended every 12 months of continuous service Replace only with a Part 46636400 germicidal replacement lamp Replace only with a Part 46636400 germicidal replacement lamp Follow the above steps to remove the lamp Replace with the new replacement lamp Fo...

Page 10: ...r the steps listed previously Return power to unit TROUBLESHOOTING GUIDE 1 Check to be sure there is correct voltage to the unit and the ballast is set for the correct voltage 2 Be sure the lamp connector is fastened securely 3 Check for loose electrical connections 4 Test with new lamp and if lamp still does not light replace ballast Replacement Part Number 46636400 Replacement UVC Lamps Set of 2...

Page 11: ...e wearing disposable non absorbent protective gloves carefully pick up the large pieces of glass with your hands 2 Vacuumtheentireareawithastandardhouseholdvacuumcleanerensuringtheremovalofalllampmaterial 3 Dispose of the pieces of glass the vacuum cleaner bag and the disposable gloves in a sealed garbage bag 4 Check with your local waste management authority for local disposal or recycling requir...

Page 12: ...ite www fieldcontrols com WARRANTY WARRANTY For warranty information about this or any Field Controls product visit For warranty information about this or any Field Controls product visit www fieldcontrols com www fieldcontrols com Field Controls Technical Support Field Controls Technical Support 1 800 742 8368 1 800 742 8368 fieldtec fieldcontrols com fieldtec fieldcontrols com Field Controls LLC...

Reviews: