Field Controls Healthy Home System Duo-2000 Manual Download Page 8

WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage 

or blindness.Never operate the Duo-2000 Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

Page 8 of 12

P/N 46638600  09/18  Rev E

HONEYCOMB AND CARBON REPLACEMENT 

If there is a need to replace the Pro-Cell honeycomb or carbon media, the subsequent procedure should be 
followed. 

WARNING:

WARNING:

  

Make sure power is disconnected from the unit before removing the unit. 

Make sure power is disconnected from the unit before removing the unit. 

NOTE: Wear disposable non-absorbent protective gloves prior to replacement procedure in case of accidental 
breakage of glass. 

1.   Disconnect the Duo Model from any power source. Look through the round sight glass hole and verify the 
 

 UV lamp is off before removing the unit from the duct or Ductboard Adaptor Plate. There should be no 

 

 blue glow along the length. 

2.  Remove the (2) Phillips head screws on the left and right hand side of the front electrical cover and  
     remove the cover.

3.   Detach the unit from the duct or Ductboard Adaptor Plate by removing the four sheet metal screws. Save 
 

 the sheet metal screws for reattaching the unit. Carefully slide unit out of duct.

4.   Remove the lamp with the following steps. Disconnect the ballast from it by unplugging the connector, see  
 

 Figure 3. Loosen lamp clip and slide through the front end of the unit, see Figure 2. Be careful no to break 

      lamp.

5.    Unscrew the end bracket by removing the hex screws, See Figure 7. Save the hex screws for reattaching 
 

 the end bracket. The end bracket is located on the opposite side of the Model than the power source. 

6.    With the end bracket taken off, the Pro-Cell honeycomb and carbon media can be slid out of the opening 
 

 in the back of the unit, see Figure 8. The honeycomb panel and the carbon media insert must be removed 

 

 together even if only one needs replacing. 

6.    Replace any removed pieces of either Pro-Cell honeycomb or carbon media with the specifi ed replacement 
 

 parts only. When sliding the replacement pieces back into the unit, check and make sure the Pro-Cell 

 

 honeycomb is placed on the inside while the carbon media is touching the outside side panel. 

7.   Once the replacements are slid all the way into the opening, attach the end bracket with previously
    removed hex screws. 

8.   Carefully insert the lamp through the grommet on the front end of the unit. Re-attach the lamp clip by 
 

 tigthening down on the plastic end cap of the lamp. Re-attach ballast by plugging connector into the four 

 

 pins of the lamp. Use a cotton cloth with isopropyl alcohol and gently clean surface of lamp.

9.   Insert Duo unit back into duct opening and attach to duct or Ductboard Adaptor plate using the four sheet  
 

 metal screws that were previously removed. The V shape of the Duo unit should face into the panel, see  

 

 Figure 5. Replace Front electrical cover and plug the quick connect power cord back into the unit.

10. Look through the round sight glass hole and verify the UV lamp is lit. There should be a blue glow along 
 

  the length. If the lamp is not lit, follow the Troubleshooting guide. 

Summary of Contents for Healthy Home System Duo-2000

Page 1: ...tion as air passes through a heating or air conditioning system They are installed in the main supply or return duct and operate continuously to automatically purify the air in the home 24 hours a day This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation treatment or prevention of any disease or condition READ...

Page 2: ...g directly at the UVC light may cause permanent eye damage or blindness Never operate the Duo 2000Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands Page 2 of 12 THIS PAGE LEFT INTENTIONALLY BLANK P N 46638600 09 18 Rev E ...

Page 3: ...of hand oils causes a reduction in the light intensity WARNING Before installing or servicing a humidifier air filter HVAC system or this unit etc always WARNING Before installing or servicing a humidifier air filter HVAC system or this unit etc always turn all power OFF and have unit unplugged Electrical shock can cause personal injury or death Never turn all power OFF and have unit unplugged Ele...

Page 4: ... Not install outdoors Product is not designed to be exposed to HVAC forced air ducted systems Do Not install outdoors Product is not designed to be exposed to outdoor elements outdoor elements WARNING Disconnect power to all equipment before beginning this installation Refer to all warning WARNING Disconnect power to all equipment before beginning this installation Refer to all warning and and cau...

Page 5: ...ded At 09 cents per kilowatt hour continuous lamp operation cost 10 5 cents per day Cycling the UVC germicidal lamp on and off degrades lamp performance much faster and shortens the filament life see Figure 6 DUO MODEL INSTALLATION INSTRUCTIONS 1 Choose a location for the Duo unit with the following considerations a The Duo unit will reduce organic buildup on an HVAC cooling heating coil by illumi...

Page 6: ... 2000 back into the duct mounting plate and tighten the mounting screws Replace the front electrical cover and plug the quick connect power cord back into the unit mounting screws MAINTENANCE WARNING Disconnect power to the transformer before commencing WARNING Disconnect power to the transformer before commencing inspection inspection and cleaning and cleaning NOTE Wear disposable non absorbent p...

Page 7: ...ector from the end of the lamp shown in Figure 3 and gently slide the lamp Unplug the lamp electrical connector from the end of the lamp shown in Figure 3 and gently slide the lamp out the front of the Duo 2000 housing Reinstall by reversing the above steps out the front of the Duo 2000 housing Reinstall by reversing the above steps NOTE If blue light leaks through any portion of plenum and or aro...

Page 8: ...ful no to break lamp 5 Unscrew the end bracket by removing the hex screws See Figure 7 Save the hex screws for reattaching the end bracket The end bracket is located on the opposite side of the Model than the power source 6 With the end bracket taken off the Pro Cell honeycomb and carbon media can be slid out of the opening in the back of the unit see Figure 8 The honeycomb panel and the carbon me...

Page 9: ... and the ballast is set for the correct voltage 2 Be sure the lamp connector is fastened securely 3 Check for loose electrical connections 4 Test with new lamp and if lamp still does not light replace ballast SPECIFICATIONS Duo 2000 UVC Photo Catalytic Air Purifier Part 17 5LAMP UVC Germicidal Lamp 50 watts UVC Length in Duct 17 3 4 inches Duo 2000 PCO TiO2 Semiconductor 3500 sq inches Weight 3 6 ...

Page 10: ...cuum the entire area with a standard household vacuum cleaner ensuring the removal of all lamp material 3 Dispose of the pieces of glass the vacuum cleaner bag and the disposable gloves in a sealed garbage bag 4 Check with your local waste management authority for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into house...

Page 11: ...g directly at the UVC light may cause permanent eye damage or blindness Never operate the Duo 2000Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands Page 11 of 12 THIS PAGE LEFT INTENTIONALLY BLANK P N 46638600 09 18 Rev E ...

Page 12: ...ite www fieldcontrols com WARRANTY WARRANTY For warranty information about this or any Field Controls product visit For warranty information about this or any Field Controls product visit www fieldcontrols com www fieldcontrols com Field Controls Technical Support Field Controls Technical Support 1 800 742 8368 1 800 742 8368 fieldtec fieldcontrols com fieldtec fieldcontrols com Field Controls LLC...

Reviews: