![Field Controls EvenAir T21 Installation And User Manual Download Page 9](http://html1.mh-extra.com/html/field-controls/evenair-t21/evenair-t21_installation-and-user-manual_2287446009.webp)
R
COM
CLS
OPN
COM
CLS
OPN
C
W/OB
EQUIPMENT
Sleeping
Living
Y1
G
W2E/Y2
TS
Model AMT
PN 580011401
Damper Actuator
Modulating
24VAC,2.4VA
COM
OPN
CLS
Made in USA
COM
OPN
CLS
G
G
W2
Y2
GE HP
E
Y2
HVAC System
Sleeping Area
Damper
Model T21WF
Thermostat (in living area)
Model TS51 (one)
Temperature Sensor
for Sleeping Area
Living Area
Damper
Y
Y
W O or B
C
C
R
R
WIRING DIAGRAM
T21WF
TS
C
N
O
O
L
T
S
R
F I E L D
Model AMT
PN 580011401
Damper Actuator
Modulating
24VAC,2.4VA
Made in USA
C
N
O
O
L
T
S
R
F I E L D
TEMPERATURE SENSOR WIRING
Place wire between brass washer
and the printed circuit board and
hand tighten screw.
The TS5 sensor can be installed
in a single gang box or directly
to the wall using the hardware
provided.
HAND
TIGHTEN
Printed circuit board
Brass washer
Use 2-conductor, 18 or 20 gage, thermostat cable to wire from
the T21WF Thermostat to the temperature sensor in the sleeping
area.
Thermistor
Thermistor
Function
Sensor
Terminal
SNR
SNR
Wire Color
White
Red
T21WF
Terminal
TS
TS
i
Single Sensor Installation
Use one (1) Model TS51 sensor.
i
Dual Sensor Installation
Use two (2) Model TS52 sensors.
Model TS52 (two)
Temperature Sensors
for Sleeping Area
(temperatures are
averaged)
Warning!
!
Turn the power to the HVAC equipment off before wiring.
-OR-
INSTALLER SECTION
Reference Electrical Wiring D
WG
: 780301202
page 9 of 16