Wiring H32 to Gas/Electric, 1H/1C

Use 5-conductor, 18 or 20 gage, thermostat cable to wire the 
H32 Wiring Hub to the equipment.

H32

Terminal

R

C

W/B

Y

G

Wire Color

Red

Blue

White

Yellow
Green

Equipment

Terminal

R, Rc, Rh

C

W, W1

Y, Y1

G

Function

24VAC Power

Common

Stg1 Heating

Fan

Stg1 Cooling

Use 2-conductor, 18 or 20 gage, thermostat cable to wire from 
the H32 Wiring Hub to the sleeping area temperature sensor.

Thermistor

Thermistor

Function

Sensor

Terminal

SNR

SNR

Wire Color

White

Red

H32

Terminal

SLP

SLP

Single

Temperature Sensor

Dual

Temperature Sensors

Place wire between brass washer 
and the printed circuit board and 
hand tighten screw.

The TS51 or TS52 can be installed 
in a single gang box or directly to 
the wall using the hardware 
provided.

HAND

TIGHTEN

Printed circuit board

Brass washer

Model TS51

Temperature

Sensor

Model TS52

Temperature

Sensor

Model TS52

Temperature

Sensor

Wiring Hub

H32

Wiring Hub

H32

SLP

SLP

SLP

SLP

Wiring H32 to Gas/Electric, 2H/2C

Wiring H32 to Heat Pump, 3H/2C

Use 7-conductor, 18 or 20 gage, thermostat cable.

Use 7-conductor, 18 or 20 gage, thermostat cable.

H32

Terminal

H32

Terminal

R

R

C

C

W/B

W/B

O

Y

Y

G

G

W2/E

W2/E

Y2

Y2

Wire Color

Wire Color

Red

Red

Blue

Blue

White

Not Used

White

Yellow

Yellow

Green

Green

Brown

Brown

Orange

Orange

Equipment

Terminal

Equipment

Terminal

R, Rc, Rh

R, Rc, Rh

C

C

W, W1

Not Used

O

Y, Y1

Y, Y1

G

G

W2

E/W2

Y2

Y2

Function

Function

24VAC Power

24VAC Power

Common

Common

Stg1 Heating

Not Used
Reversing Valve

Fan

Fan

Stg2 Heating

Aux Heating

Stg2 Cooling

Stg2 Compressor

Stg1 Cooling

Stg1 Compressor

Wired Sleeping Area Temperature Sensors

INSTALLER

page 5 of 16

P/N 780101720 3/18 Rev A

Summary of Contents for EvenAir H32

Page 1: ...ing hub is installed at the equipment It is connected to the T32 or T32WF thermostat using the existing or new 4 wire thermostat cable that normally connects the thermostat to the equipment The equipm...

Page 2: ...ith 2 stage heating and 2 stage cooling or conventional or dual fuel heat pumps with 2 compressor stages and 1 auxiliary heating stage One TS51 or two TS52 temperature sensors can be used in the sleep...

Page 3: ...irflow control is disabled and airflow is no longer displayed on the thermostat User Airflow Control can be enabled using Option 52 User turns off automatic airflow control in the User Options Read en...

Page 4: ...RS Ensure that damper installation does not cause obstruction to the damper blade WIRING Wiring Thermostat to H32 Wiring Hub Use the existing thermostat cable to wire the EvenAir commununicating therm...

Page 5: ...ng the hardware provided HAND TIGHTEN Printed circuit board Brass washer Model TS51 Temperature Sensor Model TS52 Temperature Sensor Model TS52 Temperature Sensor Wiring Hub H32 Wiring Hub H32 SLP SLP...

Page 6: ...the ER1 Electronic Receiver Module needs to be installed in the Wiring Hub Install Remote Wireless Sensors The TSER is wireless and powered by two AA batteries Two remote temperature sensors can be u...

Page 7: ...2 Place the labels on the front of the thermostat over the battery cover The TSRC can be used to turn Econo Cooling ECool On of Off The TSRC can be wall mounted or can sit on a bedside table When the...

Page 8: ...y Required when using dual fuel heat pumps TSER Sensor installed in Master Bedroom ER1 Electronic Receiver Module Inside Tu Day Upstairs Auto Downstairs Airflow HEAT Schedule AUTO FAN MENU MODE Heat S...

Page 9: ...edroom See Note 2 Note 1 Note 2 Use one TS51 sensor for single sensor installations Use two TS52 sensors for dual sensor installations Number of wires used in cable Inside Tu Day Upstairs Auto Downsta...

Page 10: ...ooling calls The equipment terminal can be designated as DS BK ODD or DHUM The Wiring Hub DS terminal is normally 24 VAC and goes to 0VAC when de humidification is active Option 42 turns de humidifica...

Page 11: ...damper should open each hour based on ASHRAE 62 2 calculations and the damper size Factory Default OFF Range On or Off Factory Default 30 minutes Range 0 to 60 Option NEXT ENTER Option NEXT ENTER Sele...

Page 12: ...ON to control Whole House Fan or Economizer using a 1 to 12 hour timer set in the thermostat by the homeowner using the User Menu The timer starts when the System is switched to ECool When the timer...

Page 13: ...omizer Cooling Cooling Enable Free Cooling using Dampers and Equipment Fan Dampers and Fan controlled by Temperature Dampers and Fan Outdoor Temperature Limit Dampers and Fan Control by Timer Select O...

Page 14: ...airs bedroom is too cold or too hot at night The Nighttime Airflow Control option directs more airflow to the sleeping area and less airflow to the unoccupied living area If the downstairs bedroom is...

Page 15: ...t 2 Cool Wired temperature sensor for the sleep area Dual sensor installation Wireless temperature sensor for the sleep area Single or Dual sensor installation Requires ER1 Electronic receiver module...

Page 16: ...rols product visit www fieldcontrols com Field Controls Technical Support 1 800 742 8368 fieldtec fieldcontrols com Phone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC c Field...

Reviews: