Field Controls EvenAir H32 Installation Manual Download Page 2

Screw attaches cover to base.

Cover.

Optional eLink Radio Module plugs into connectors.

24VAC Power Indicator.

Terminals for wiring

to HVAC equipment.

Terminals for upstairs  

wired temperature sensor

Terminals for humidifier

Terminals for outdoor temperature sensor

Terminals for ERV/HRV

Terminals for Fresh Air Damper

Terminals for Whole House Fan or Economizer Dampers

Terminals for communicating EvenAir Thermostat

Connector for downstairs living area 
plug&play modulating damper

Connector for upstairs sleeping area 
plug&play modulating damper.

Relay

Relay

Relay

Relay

Relay

Relay

Relay

Relay

Relay

Relay

R

C

W/B

O

Y

G

W2/E

Y2

DS

HFR

HFR

SENSORS TSTAT

LIVING SLEEP

DAMPER DAMPER

WH FAN FR AIR

DAMPR DAMPR

HVAC

ODT

ODT

SLP

SLP

GND

+5V

SA

SB

OPN

OPN

COM

COM

24V

24V

ER
V/HR

V

ER
V/HR

V

Gas/electric equipment with 2-stage heating and 2-stage 
cooling or conventional or dual fuel heat pumps with 2 
compressor stages and 1 auxiliary heating stage.

One TS51 or two TS52 temperature sensors can be used in the 
sleeping area.

One or two TSER wireless temperature sensors can be used in 
the sleeping area. The ER1 radio module must be installed in 
the wiring hub when wireless sensors are used.

Round or rectangular dampers using the AMJ plug and play 
actuator and up to 1 inch static pressure. Up to 6 dampers can 
be daisy chained to define the upstairs sleeping area or 
downstairs living area.

Wiring hub is powered by 24VAC from the HVAC equipment R 
and C terminals.

FEATURES

COMPATIBLE EQUIPMENT  

WIRED TEMPERATURE SENSORS 

WIRELESS TEMPERATURE SENSORS 

MODULATING DAMPERS  

POWER 

WIRING HUB OVERVIEW

LED indicator.

POWER INDICATOR 

Thank you for purchasing the EvenAir System from Field Controls. The EvenAir products are compatible 
with any HVAC system having accessible 24VAC terminals.

page 2 of 16

P/N 780101720 3/18 Rev A

Summary of Contents for EvenAir H32

Page 1: ...ing hub is installed at the equipment It is connected to the T32 or T32WF thermostat using the existing or new 4 wire thermostat cable that normally connects the thermostat to the equipment The equipm...

Page 2: ...ith 2 stage heating and 2 stage cooling or conventional or dual fuel heat pumps with 2 compressor stages and 1 auxiliary heating stage One TS51 or two TS52 temperature sensors can be used in the sleep...

Page 3: ...irflow control is disabled and airflow is no longer displayed on the thermostat User Airflow Control can be enabled using Option 52 User turns off automatic airflow control in the User Options Read en...

Page 4: ...RS Ensure that damper installation does not cause obstruction to the damper blade WIRING Wiring Thermostat to H32 Wiring Hub Use the existing thermostat cable to wire the EvenAir commununicating therm...

Page 5: ...ng the hardware provided HAND TIGHTEN Printed circuit board Brass washer Model TS51 Temperature Sensor Model TS52 Temperature Sensor Model TS52 Temperature Sensor Wiring Hub H32 Wiring Hub H32 SLP SLP...

Page 6: ...the ER1 Electronic Receiver Module needs to be installed in the Wiring Hub Install Remote Wireless Sensors The TSER is wireless and powered by two AA batteries Two remote temperature sensors can be u...

Page 7: ...2 Place the labels on the front of the thermostat over the battery cover The TSRC can be used to turn Econo Cooling ECool On of Off The TSRC can be wall mounted or can sit on a bedside table When the...

Page 8: ...y Required when using dual fuel heat pumps TSER Sensor installed in Master Bedroom ER1 Electronic Receiver Module Inside Tu Day Upstairs Auto Downstairs Airflow HEAT Schedule AUTO FAN MENU MODE Heat S...

Page 9: ...edroom See Note 2 Note 1 Note 2 Use one TS51 sensor for single sensor installations Use two TS52 sensors for dual sensor installations Number of wires used in cable Inside Tu Day Upstairs Auto Downsta...

Page 10: ...ooling calls The equipment terminal can be designated as DS BK ODD or DHUM The Wiring Hub DS terminal is normally 24 VAC and goes to 0VAC when de humidification is active Option 42 turns de humidifica...

Page 11: ...damper should open each hour based on ASHRAE 62 2 calculations and the damper size Factory Default OFF Range On or Off Factory Default 30 minutes Range 0 to 60 Option NEXT ENTER Option NEXT ENTER Sele...

Page 12: ...ON to control Whole House Fan or Economizer using a 1 to 12 hour timer set in the thermostat by the homeowner using the User Menu The timer starts when the System is switched to ECool When the timer...

Page 13: ...omizer Cooling Cooling Enable Free Cooling using Dampers and Equipment Fan Dampers and Fan controlled by Temperature Dampers and Fan Outdoor Temperature Limit Dampers and Fan Control by Timer Select O...

Page 14: ...airs bedroom is too cold or too hot at night The Nighttime Airflow Control option directs more airflow to the sleeping area and less airflow to the unoccupied living area If the downstairs bedroom is...

Page 15: ...t 2 Cool Wired temperature sensor for the sleep area Dual sensor installation Wireless temperature sensor for the sleep area Single or Dual sensor installation Requires ER1 Electronic receiver module...

Page 16: ...rols product visit www fieldcontrols com Field Controls Technical Support 1 800 742 8368 fieldtec fieldcontrols com Phone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC c Field...