SERVICE   

 

 

 

 

 

 

 

 

 

 

 

 
MERV13 Pre Filter is recommended to replace minimum every six (6) months.  The service light turns from 
green to yellow after five (5) months and to red after six (6) months.  Change the pre filter before the red LED 
light illuminates. 
 
UVC Germicidal Ultraviolet Lamps is recommended to be replaced every twelve (12) to twenty four (24) 
months.  The service light turns from green to yellow as a thirty (30) notice to replace lamps.  The service light 
turns to red when it is time to replace lamps. 
 
Choice Options available for Formaldehyde Post Filter or Carbon Post Filter 
Formaldehyde (potassium permanganate) Post Filter is an onsite installed option.  Order Field Controls part 
number 1RK026 model number 1RK026. Field Controls recommends replacing minimum every six (6) months.  
The service light turns from green to yellow after five (5) months and to red after six (6) months.  Change the 
post filter before the red LED light illuminates. 
 
Carbon Post Filter is an onsite installed option. Order Field Controls part number 46728500 model number 
1RK027. Field Controls recommends replacing minimum every six (6) months.  The service light turns from 
green to yellow after five (5) months and to red after six (6) months.  Change the post filter before the red LED 
light illuminates. 
 
 
 

CHANGING THE FILTER 

1.  Always wear protective eye goggles to prevent physical harm by UVC Ultraviolet light. 

 

2.  Unplug the power cord from main outlet on the Cube unit. 

 

3.  Unscrew the four (4) screws from both the MERV13 filter cover and pull out the loaded MERV13 filter 

and replace. Discard as per local regulations if required. 

 

4.  The correct placement of the new MERV13 filter is with the wire side down stream of airflow. 

 

5.  Check that airflow arrow on MERV13 is pointing in the same direction as the airflow arrow found on 

filter frame panel. 

 

6.  Reattach filter cover and tighten four (4) cover screws. 

 

 
 
 
 
 
 

 
 

Summary of Contents for Cube

Page 1: ...Field Controls 2630 Airport Road Kinston NC 28504 252 522 3031 www fieldcontrols co ...

Page 2: ...cations 4 Operation 5 Air Cycles HHSC 5 Service 6 Changing Filters 6 Replacement Filters and Germicidal UVC Lamps 7 Resetting Remote Service Panel 8 Installation 9 Transitions for In Duct Mounting 9 10 Electrical Schematic 11 Performance Data 12 Warranty 13 ...

Page 3: ...sult The Cube is rated for standard ambient air temperatures during heating and cooling functions The Cube is not rated for temperatures in excess of 125 Degrees Fahrenheit 52 Degrees Celsius Do not attempt to clean the PRO Cell honeycomb catalyst with cleaning solutions The PRO Cell catalyst is radiated with short wave germicidal ultraviolet light during periods of airflow and is self cleaning Do...

Page 4: ... 23 H x 31 W x 29 D 585mm H x 787mm W x 737mm D Standard with MERV13 Media Pre Filter and 3 PRO Cell Modules 1 Master Module MM 2 Slave Module SM CFM in W C pa 1200 0 19 47 326 1600 0 26 64 763 2000 0 35 87 181 Frame body between flanges Flange height Cover for MERV13 Pre Filter W L H 1 2 all around W H D 24 3 4 30 3 4 22 12mm all around 3 5 16 19 1 2 620mm 784mm 560mm 84mm 484mm 12mm Outside dime...

Page 5: ...The length of operation depends on the location of the facility in relation to point source of pollution such as refineries processing plants automobile traffic hair salons dog motels fitness center locker rooms and areas that produce high levels of pollutants Individuals that are sensitive to mold spores dust mites chemicals or have respiratory problems such as asthma emphysema and chronic allerg...

Page 6: ... 5 months and to red after six 6 months Change the post filter before the red LED light illuminates Carbon Post Filter is an onsite installed option Order Field Controls part number 46728500 model number 1RK027 Field Controls recommends replacing minimum every six 6 months The service light turns from green to yellow after five 5 months and to red after six 6 months Change the post filter before t...

Page 7: ... germicidal lamp clamp thumb screw located at the far end of the UVC germicidal lamp so as to be able to carefully remove the lamp through the rubber grommet on the front of the module IMPORTANT AVOID TOUCHING THE NEW UVC GERMICIDAL LAMPS WITH BARE HANDS AS THE OIL ON THE SKIN CAN IMPEDE LAMP PERFORMANCE OR CAUSE PERMATURE FAILURE OF LAMP ILLUMINATION THE USE OF COTTON GLOVES OR PAPER TOWELS IS PR...

Page 8: ...ers and UVC germicidal lamps are available from your authorized Field Controls Wholesaler Distributor or Contractor You may contact Field Controls for information on a Wholesaler Distributor or Contractor at Field Controls 2630 Airport Road Kinston NC 28504 252 522 3031 www fieldcontrols com PART NUMBER MODEL DESCRIPTION 46636500 TrioRM13 2025 20x25x4 MERV13 Repl Media Pre Filter 6 MCTN 46636700 T...

Page 9: ... certain to provide for a door open access to service covers TRANSITIONS FOR IN DUCT MOUNTING Metal adapter of 18 gauge sheet metal or greater and insulated should be fabricated to make suitable transitions Attach the transitions to the Cube and fasten with 10 x 1 2 self tapping sheet metal screws See Figure 2 illustration on following page 1 Tape all seams between the air handler blower return si...

Page 10: ...FIGURE 2 10 ...

Page 11: ...ELECTRICAL SCHEMATIC 11 ...

Page 12: ...PERFORMANCE DATA 12 ...

Page 13: ...WARRANTY 13 Refer to www fieldcontrols com for complete warranty statement ...

Reviews: