Field Controls CK-43 Instruction Manual Download Page 2

 

Page 2

INSTALLATION INSTRUCTIONS 

M

OUNTING 

J

UNCTION 

B

OX

 

The junction box can be mounted at the venter or remotely mounted away from 
the venter. (See Figure 1 & Figure 2) 

1.  Remove one of the knockouts from the  side of the junction box where the 

pressure switch is mounted. Install  the flexible conduit connector onto the 
CK-43 junction box and secure with fastening nut. If remote mounting the 
CK-43 junction box, mount the flexible conduit connector onto a 2" x 4"  
installer supplied junction box. 

2.  Fasten the flexible conduit from the  SWG Venter into the conduit 

connector. Mount the CK-43 junction box or installer supplied 
junction box onto  the wall or floor joist without straining the 
flexible conduit. Fasten the CK-43 junction box through the four 
dimpled locations on the base of the  box. (See Figure 3)  

P

RESSURE 

S

WITCH 

S

ENSING 

T

UBE 

I

NSTALLATION

 

1.  Attach the 1/4 inch tubing connector to the pressure tube on the 

SWG Venter.  (See Figure 3)  

2. Connect the supplied 1/4" aluminum tubing to the tubing 

connector. Route the tubing to the CK-43 junction box  and 
connect the tubing to the pressure switch. When routing the 
tubing, avoid kinking the tubing by bending the  tubing too 
sharply. 

For remote mounted CK-43 Junction Box, use a 1/4" OD copper, 
aluminum or plastic tubing and route the tubing to avoid contact with 
any heat source. 

Figure 1

Figure 2

Figure 3

Summary of Contents for CK-43

Page 1: ...luminum tubing 1 1 4 inch tubing connector 1 Flexible conduit connector 1 4 MG1 Barometric Draft Control or 5 AF Barometric Draft Control This device MUST be installed by a qualified agency in accordance with the manufacturers installation instructions The definition of a qualified agency is any individual firm corporation or company which either in person or through a representative is engaged in...

Page 2: ... the CK 43 junction box or installer supplied junction box onto the wall or floor joist without straining the flexible conduit Fasten the CK 43 junction box through the four dimpled locations on the base of the box See Figure 3 PRESSURE SWITCH SENSING TUBE INSTALLATION 1 Attach the 1 4 inch tubing connector to the pressure tube on the SWG Venter See Figure 3 2 Connect the supplied 1 4 aluminum tub...

Page 3: ... at the front corners of the collar Bend 90 degrees 1 4 inch behind the single hole on the straps 2 Insert clamping screw in ears on collar and bolt the remainder of the collar together 3 Hold the collar against the side of the flue in the exact position it is to be installed shown by dotted lines and mark the outline of the collar on the flue 4 Cut a hole in the flue about 1 2 inside of this outl...

Page 4: ...e 8 DO NOT move the weight attached directly to the gate this is used only for balancing at the factory ADJUSTING THE DRAFT CONTROL WITH 5 AF Vertical Flues Mounting The control is shipped for installation in a vertical flue The adjustment weight should be in the right hand slot when you face the control See Figure 9 Horizontal Flues Mounting For hori zontal flues remove the weight from the right ...

Page 5: ...the timer adjustment counterclockwise For timer that looks like Figure 12 Rotate the timer adjustment on the timer counterclockwise to increase the operation time To decrease the operation time rotate the timer adjustment clockwise Typical post purge time should be between 3 to 5 min WIRING CAUTION Disconnect electrical power when wiring power venter NOTE If using this control kit with an electron...

Page 6: ...nter operating a Check pressure switch adjustment b Check wiring connections between pressure switch and burner c Check pressure switch for conti nuity across terminals during venter operation 2 Venter does not activate when thermostat calls for heat a Check wiring b Check relay for proper operation 3 Flue gas odor a Check system draft b Check for negative pressure in building c Check post purge t...

Page 7: ..._ INSTALLER S NAME _____________________________________________________ INSTALLER S COMPANY _________________________________________________ INSTALLER S PHONE NO ________________________________________________ DATE OF INSTALLATION _________________________________________________ CK 43 Control Kit ...

Page 8: ...Page 8 P N 46190700 Rev D 11 07 ...

Reviews: