background image

24 VAC SYSTEM CONTROL KIT  

Model:

 CK-92F and CK-92FG 

Designed for use with the SWG Series Power Venter for controlling Natural 
Gas or L.P. Gas appliances with a 24 VAC Gas Valve and a 30-millivolt 
controlled Natural or L.P. Gas Water Heater. 
 

I

TEMS INCLUDED IN KIT

:

 

1) Junction box with mounted pressure switch and post purge timer 
1) Fan control gas pressure switch with built in post purge option 
1) 2 ft. length of 1/4 inch aluminum tubing 
1) 1/8" NPT x 3 inch pipe nipple 
1) 1/8" NPT x 1/4 inch OD tubing elbow 
1) 1/8" NPT pipe tee 
1) TCA-1 Thermocouple Adaptor (CK-92F) 
1) TCA-2 Left Handed Thermocouple Adaptor (CK-92FG) 
1) 6 ft. length of 12-2 wire 
1) 8 inch jumper wire 
2) Flexible conduit connector 
2) GSK-3 Spillage Switch 
1)  1/4 inch tubing connector 

 

DO NOT DESTROY 

THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT 

 

 

 

Summary of Contents for 46285400

Page 1: ...witch and post purge timer 1 Fan control gas pressure switch with built in post purge option 1 2 ft length of 1 4 inch aluminum tubing 1 1 8 NPT x 3 inch pipe nipple 1 1 8 NPT x 1 4 inch OD tubing elb...

Page 2: ...2F junction box or installer supplied junction box onto the wall or floor joist without straining the flexible conduit Fasten the CK 92F junction box through the four dimpled locations on the base of...

Page 3: ...s supply to gas valve before plug removal 2 Replace the pressure tap plug with the 1 8 pipe nipple and pipe tee Install pressure tap plug at the bottom of the pipe tee See Figure 6 3 Install the gas p...

Page 4: ...er when wiring power venter Wire the venter motor and controls in accordance with the National Electrical Code manufacturer s recommendations and or applicable local codes UNITS MUST BE GROUNDED Check...

Page 5: ...wire from this terminal and reroute to T1 on CK 92F 4 With boilers connect T3 on CK 92F to hot side of gas valve if standing pilot or to terminal TH W 24 V THS or T1 if spark ignition NOTE Remember th...

Page 6: ...wer to the gas pressure switch 2 Adjust the thermostat to call for heat with the venter inoperative Allow approximately 2 minutes of flue gas spillage for the spillage switches to sense the spillage a...

Page 7: ...__ INSTALLER S NAME _____________________________________________________ INSTALLER S COMPANY _________________________________________________ INSTALLER S PHONE NO ___________________________________...

Page 8: ...Page 8 P N 46285400 Rev C 10 03...