Operating instructions WPM Gateway IoT
51/76
Set up WPM Gateway
8.4
Positioning sensors on the tool screen
Before sensors can be positioned on the tool screen, a tool screen must be assigned to the data
holder for the respective top or bottom side (see Chapter 8.3 "Data holder – Tool screen assign-
ment" on page 50).
Open view:
Main menu => Data holder =>
=> Tool screen
Fig. 8-6 Positioning sensors on the tool screen
1) Use the
Top Bottom
button to select the top or bottom tool screen for the sensor.
2) Select a sensor in the sensor list and set the position to the top or bottom.
3) The icon of the sensor appears in the middle of the tool screen.
–
The icon can be dragged and dropped to the appropriate position within the tool screen.
–
The coordinates of the sensor are displayed as relative (x,y) coordinates.
4) To accept the position, press the
Save
button.
When the sensor is placed, it is displayed in the centre of the tool screen. If several sensors are
placed, they are all directly above each other. The currently selected sensor is on top.
1
2
3