Reproduction forbidden without Fibocom Wireless Inc. written authorization - All Rights Reserved
FIBOCOM L610-LA Series Hardware Guide
Page 44 of
49
Signal
VL
VH
Unit
Min
Max
Min
Max
Digital input
-0.3
0.6
1.2
2.0
V
Digital
output
-
0.45
1.35
-
V
Parameter
I/O
Min
Typ
Max
Unit
VBAT
I
3.4
3.8
4.3
V
USIM_VDD
O
1.7/2.75
1.8/2.85
1.9/2.95
V
5.4 Environmental Reliability Requirements
Test Item
Test Condition
Low temperature
storage test
Temperature -45
℃
±3
℃
, 24 hours in shutdown state
High temperature
storage test
Tempe90
℃
±3
℃
, 24 hours in shutdown state
Temperature
shock test
In shutdown state, 0.5 hour at -40
℃
and +85
℃
ambient temperatures respectively,
the temperature conversion time
< 3min, for 24 cycles
High temperature
and humidity test
Tempe65
℃
±3
℃
, humidity 90~95%RH, 88 hours in shutdown state
Low temperature
operating test
Temperature -30
℃
±3
℃
, 24 hours in operating state
High temperature
operating test
Tempe75
℃
±3
℃
, 24 hours in operating state
Vibration test
Conduct vibration test according to the requirements shown in the following table:
Frequency
Random Vibration ASD (Acceleration
Spectral Density)
5~20Hz
0.96m
2
/s
3
20~500Hz
0.96m
2
/s
3
(20Hz), other -3dB/octave