background image

Warning for Your Protection 

1. Read these instructions. 

2. Keep these instructions. 

3. Heed all warnings. 

4. Follow all instructions. 

5. Do not use this apparatus near water. 

6. Clean only with a dry cloth. 

7. Do not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions. 

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 

9. Do not defeat the safety purpose of the polarized or grounding‐type plug. A polarized plug has two blades with one wider than the other. A 
grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug 
does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the 
apparatus. 

11. Only use attachments/accessories specified by the manufacturer. 

12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use 
caution when moving the cart/apparatus combination to avoid injury from tip‐over.    

13. Unplug this apparatus during lightning storms or when unused for long periods of time. 

14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power‐supply 
cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped. 

The apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as vases or drink cups, shall be placed on the 
apparatus. 

 “WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.” 

General Installation Instructions 

Please consider these general instructions in addition to any product‐specific instructions in the “Installation” chapter of this manual. 

Unpacking 

Check the equipment for any transport damage. If the unit is mechanically damaged, if liquids have been spilled or if objects have fallen into the 
unit, it must not be connected to the AC power outlet, or it must be immediately disconnected by unplugging the power cable. Repair must only be 
performed by trained personnel in accordance with the applicable regulations. 

Installation Site 

Install the unit in a place where the following conditions are met: 

 

The temperature and the relative humidity of the operating environment must be within the specified limits during operation of the 
unit. Values specified are applicable to the air inlets of the unit. 

 

Condensation may not be present during operation. If the unit is installed in a location subject to large variations of ambient 
temperature (e.g. in an OB‐van), appropriate precautions must be taken. 

 

Unobstructed air flow is essential for proper operation. Ventilation openings of the unit are a functional part of the design and must 
not be obstructed in any way during operation (e.g. ‐ by objects placed upon them, placement of the unit on a soft surface, or 
improper installation of the unit within a rack or piece of furniture). 

 

The unit must not be unduly exposed to external heat sources (direct sunlight, spot lights). 

Ambient Temperature 

Units and systems by FiberPlex are generally designed for an ambient temperature range (i.e. temperature of the incoming air) of +5...+40 °C. 
When rack mounting the units, the following facts must be considered: 

 

The permissible ambient temperature range for operation of the semiconductor components is 0 °C to +70 °C (commercial 
temperature range for operation). 

 

The air flow through the installation must allow exhaust air to remain cooler than 70 °C at all times. 

 

Average temperature increase of the cooling air shall be about 20 C°, allowing for an additional maximum 10 C° increase at the 
hottest components. 

If the cooling function of the installation must be monitored (e.g. for fan failure or illumination with spot lamps), the exhaust air temperature must 
be measured directly above the modules at several places within the enclosure. 

Grounding and Power Supply 

Grounding of units with mains supply (class I equipment) is performed via the protective earth (PE) conductor integrated in three pin Phoenix™ 
connector. Units with battery operation (< 60 V, class III equipment) must be earthed separately. Grounding the unit is one of the measures for 
protection against electrical shock hazard (dangerous body currents). Hazardous voltage may not only be caused by defective power supply 
insulation, but may also be introduced by the connected audio or control cables. 

This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. If 
the attachment plug needs to be changed, refer servicing to qualified personnel. 

Summary of Contents for FOM-3841

Page 1: ...USER MANUAL 4 Channel POTS Telephone Fiber Converter FOM 3841 3842...

Page 2: ...cable Repair must only be performed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperat...

Page 3: ...sal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer...

Page 4: ...nal telephone line cord wiring Multimode optics on the units can extend the distance to 2km while singlemode optics can further extend the distance to 20km A typical link consists of an FOM 3841 conne...

Page 5: ...Typical Application...

Page 6: ...Features Rear Indicators Connections Figure 1 FOM 3841 3842 Rear 1 1 1 2 2 3 3 4 6 5 6...

Page 7: ...escription 1 2 3 Ring 4 Tip 5 6 Optical Fiber Connections This position may be a pair of ST connectors LC connectors or an SFP slot if so ordered Optics Status LED Status Description Steady Green Opti...

Page 8: ...he power from the card for 30 seconds and then plug it in again so that the fuse on the card has time to reset If the Power led is still red or not a constant green replace the card Off Card failure o...

Page 9: ...M series cards may be installed into a RMC 5000 rack chassis A loaded RMC 5000 is shown below Figure 3 FOM Card being installed into an RMC 5000 Standalone using SAC 1 AC Single FOM series cards may b...

Page 10: ...dule that you use to disengage the module from a port Handling Warnings SFP Modules are static sensitive To prevent damage from electrostatic discharge ESD it is recommended to attach an ESD preventat...

Page 11: ...p Open the bail clasp on the SFP Module with your finger in a downward direction Actuator Button Gently press the actuator up or in while pulling the body of the SFP Module to release the SFP Module f...

Page 12: ...DIP Switch Settings Switch Designations As shown below each DIP switch is assigned a numerical designation which is keyed to the descriptive text Figure 5 FOM 3841 3842 DIP Switches...

Page 13: ...annel 4 Ring Mode DOWN OFF Normal Ringing UP ON Unbalanced Ring S3 1 Reserved S3 2 S3 3 S3 4 S3 5 Remote Configuration DOWN OFF Allow remote configuration UP ON Inhibit remote configuration S3 6 Reser...

Page 14: ...Specifications Figure 6 FOM 3841 3842 Dimensions 80 20 4 11 50X 50 12 7 5 22X...

Page 15: ...iant SFP Modules ELECTRICAL SPECIFICATIONS Min Typ Max Unit Power Requirement Voltage Range 20 24 34 V Supply Current 250 mA Min Typ Max Unit Environmental Storage Temperature 40 85 C Operating Temper...

Page 16: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 UMFOM384x 170822...

Reviews: