o
the device added to the Z-Wave network,
o
parameter 151 is set to 1 or 2.
2.
Press and hold UP or DOWN switch for at least 3 seconds
3.
Press and hold the same switch again for at least 3 seconds.
4.
Press and hold the same switch again for at least 3 seconds.
5.
The device will perform the calibration process, completing full cycle – up, down and up
again.
6.
Test whether the positioning works correctly.
Calibration using the B-button
1.
Make sure:
o
the device is supplied,
o
the device added to the Z-Wave network,
o
parameter 151 is set to 1 or 2.
2.
Press and hold the B-button.
3.
Wait for the LED to glow white.
4.
Quickly release and click the B-button again.
5.
The device will perform the calibration process, completing full cycle – up, down and up
again
6.
Test whether the positioning works correctly.
Calibration using parameter
1.
Make sure:
o
the device is supplied,
o
the device added to the Z-Wave network,
o
parameter 151 is set to 1 or 2.
2.
Set the parameter 150 value to 2
3.
The device will perform the calibration process, completing full cycle – up, down and up
again
4.
The parameter 150 value will be set to 1 after calibration finishes.
5.
Test whether the positioning works correctly.
Slats positioning in Venetian blinds mode
Calibration using a connected momentary switch
1.
Make sure:
o
the device is supplied,
o
the momentary switch is connected to S1 and S2 terminals,
o
the device added to the Z-Wave network,
o
parameter 151 is set to 2,