17
ADVAnCED PARAMETERS
12. First channel - time parameter for delay/auto ON/OFF modes
This parameter allows to set time parameter used in timed modes.
Available settings:
0
(0.1s)
, 1-32000
(1-32000s, 1s step) - time
parameter
Default setting:
50
(50s)
Parameter size:
2
[bytes]
13. First channel - pulse time for flashing mode
This parameter allows to set time of switching to opposite state in
flashing mode.
Available settings:
1-32000
(0.1-3200.0s, 0.1s step) - time param-
eter
Default setting:
5
(0.5s)
Parameter size:
2
[bytes]
15. Second channel - operating mode (FGS-223 only)
This parameter allows to choose operating for the 1st channel con-
trolled by the S2 switch.
Available settings:
0
- standard operation
1
- delay On
2
- delay OFF
3
- auto On
4
- auto OFF
5
- flashing mode
Default setting:
0
Parameter size:
1
[byte]
16. Second channel - reaction to switch for delay/auto ON/OFF
modes (FGS-223 only)
This parameter determines how the device in timed mode reacts to
pushing the switch connected to the S2 terminal.
Available settings:
0
- cancel mode and set target state
1
- no reaction to switch - mode runs until it ends
2
- reset timer - start counting from the beginning
Default setting:
0
Parameter size:
1
[byte]
17. Second channel - time parameter for delay/auto ON/OFF
modes (FGS-223 only)
This parameter allows to set time parameter used in timed modes.
Available settings:
0
(0.1s)
, 1-32000
(1-32000s, 1s step) - time
parameter
Default setting:
50
(50s)
Parameter size:
2
[bytes]
NOTE
When parameter 15
value is set to 5, then
parameter 16 value
must be set to 0.
i
Summary of Contents for FGS-2x3
Page 2: ......