background image

8

OPERATInG THE DEVICE

Resetting the Door/Window Sensor 2: 

Reset procedure allows to restore the device back to its factory set-

tings, which means all information about the Z-Wave controller and 

user configuration will be deleted. 
In order to reset the device:
1.  Open the cover.
2.  Remove the battery.
3.  Install the battery while holding both TMP buttons.
4.  Visual LED indicator will be flashing slowly for 5 seconds - keep 

holding the buttons.

5.  Release one button when the LED indicator starts flashing quickly.  
6.  Click released button once to confirm launching of reset procedure.
7.  Wait a few seconds until a long blink of the LED indicator. Do not 

remove the battery.

8.  Visual LED indicator will blink 5 times quickly to confirm the reset.

NOTE

Resetting the device is 

not the recommend-

ed way of removing 

the device from the 

Z-Wave network. Use 

reset procedure only 

if the primary con-

troller is missing or 

inoperable. Certain 

device removal can be 

achieved by the pro-

cedure of removing 

described in “Adding/

removing the device” 

on page 5.

i

Replacing the battery: 

In FIBARO Home Center controller current battery level is displayed 

in the interface. If a battery icon turns red, it means the battery needs 

replacement.

NOTE

Opening the casing 

may result in trigger-

ing an alarm. To avoid 

it, remove the asso-

ciations for the 3rd 

group.

i

Notification report: 

The device uses notification Command Class to report different 

events.

notification Type

Event

Home Security

Tampering, product covering 

removed

Access Control

Door/window opened

Access Control

Door/window closed

Power Management

Replace battery now

Heat Alarm

Overheat detected, unknown 

location

Heat Alarm

Underheat detected, unknown 

location

NOTE

Command Class Ba-

sic value is related to 

the status of contact 

sensor (0x00 - closed, 

0xFF - opened, on de-

fault setting of param-

eter 1. “Door/window 

state “).

i

Summary of Contents for FGDW-002

Page 1: ...1 Description and features 3 2 Basic activation 4 3 Adding removing the device 5 4 Physical installation 6 5 Operating the device 7 6 Association 9 7 Advanced parameters 10 8 Specifications 14 9 Regulations 15 O P E R A T I N G M A N U A L EN v1 1 ...

Page 2: ...fy the compliance with additional standards General information about the FIBARO System FIBARO is a wireless smart home automation system based on the Z Wave protocol All of available devices can be controlled through a computer PC or Mac smartphone or tablet Z Wave devices are not only receivers but can also repeat the signal increasing the Z Wave network s range It gives advantage over tradition...

Page 3: ...with the Z Wave Plus standard Changing the device s status will automatically send signal to the Z Wave controller and associated devices Sensor can be used to trigger scenes and wherever there is a need for information about opening or closing of doors windows garage doors etc Opening is detected by separating the sensor s body and the magnet In addition the FIBARO Door Window Sensor 2 is equippe...

Page 4: ...ctivation 2 Basic activation 1 Take off the cover 2 Remove the battery blocker 3 Close the cover 4 Add the device see Adding removing the device on page 5 5 Install the device see Physical installation on page 6 ...

Page 5: ...ce learning mode allowing to remove the device from existing Z Wave network To remove the device from the Z Wave network 1 Place the Door Window Sensor 2 within the direct range of your Z Wave controller 2 Set the main controller into remove mode see the controller s manual 3 Quickly three times press one of the TMP buttons while the other button is pressed 4 Wait for the removing process to end 5...

Page 6: ...r on the magnet 4 Stick the magnet onto the moving part of the door window no further than 5mm from the sensor Correct positioning of the magnet in relation to the Sensor vertical line marks should align Positioning of the Sensor and the magnet max 5 mm NOTE It is possible to in stall the device with screws not included We recommend using 2 5mm x 16mm coun tersunk head screws with 5mm head diam et...

Page 7: ...lows to control the device directly Waking up the Door Window Sensor 2 The Door Window Sensor 2 needs to be woken up to receive informa tion about the new configuration from the controller like parameters and associations To wake up the sensor manually click one of the TMP buttons while the other button is pressed Controlling the Door Window Sensor 2 with FIBARO Home Center controller After adding...

Page 8: ... Wave network Use reset procedure only if the primary con troller is missing or inoperable Certain device removal can be achieved by the pro cedure of removing described in Adding removing the device on page 5 i Replacing the battery In FIBARO Home Center controller current battery level is displayed in the interface If a battery icon turns red it means the battery needs replacement NOTE Opening t...

Page 9: ...are to be associated 4 Save the changes 5 Wake up the device manually or wait for the next automatic wake up NOTE Association allows transfer of control commands between devices without par ticipation of the main controller Direct range between devices is recom mended i The Door Window Sensor 2 in 2nd and 3rd group allows to control 5 devices regular or multichannel per an association group LifeLi...

Page 10: ...g 6 Parameter size 1 byte Wake up interval Available settings 0 or 3600 64800 in seconds 1 18h 3600s 1h step Default setting 21600 6h The Door Window Sensor will wake up after each defined time inter val and always try to connect with the main controller After a suc cessful communication attempt the sensor will update configuration parameters associations and settings and will go into standby mode...

Page 11: ...osing parameter 13 Default setting 0 Parameter size 1 byte 12 Association for opening value sent Value sent to devices in 2nd association group when opening is detected The value of 0 turns OFF the device 255 turns it ON In case of associating devices allowing smooth control values 1 99 allow to set an associated device to a specified level Available settings 0 99 or 255 Default setting 255 Parame...

Page 12: ...ife will shorten Available settings 0 temperature measurements disabled 5 32400 time in seconds Default setting 300 5min Parameter size 2 bytes 51 Temperature reports threshold This parameter defines the change of temperature in comparison with last reported resulting in temperature report being sent to the main controller Available settings 0 temperature reports based on threshold disabled 1 300 ...

Page 13: ...low temperature alarms enabled Default setting 0 Parameter size 1 byte 55 High temperature alarm threshold If temperature is higher than set value overheat notification will be sent and high temperature alarm will be triggered if activated Available settings 1 600 0 1 60 C 0 1 C step Default setting 350 35 Parameter size 2 bytes 56 Low temperature alarm threshold If temperature is lower than the s...

Page 14: ...ANZ 869 0 MHz RU up to 50m 164ft outdoors up to 40m 131ft indoors depending on terrain and building structure Indoor use only 0 40 C 32 104 F 0 60 C 32 140 F 0 5 C 0 9 F 71 x 18 x 18 mm 2 8 x 0 7 x 0 7 inch 8 Specifications NOTE Radio frequency of individual device must be same as your Z Wave controller Check information on the box or consult your dealer if you are not sure i CAUTION Using batteri...

Page 15: ...fferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes and modifications not expressly approved by the manufactu rer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules Industry Canada IC Compliance Notice This device complies with Industry Canada li...

Page 16: ...可 公司 商號或使用 者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現 有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波輻射性 電機設備之干擾 Warning This product is not a toy Keep away from children and animals Declaration of conformity Hereby Fibar Group S A declares that the device is in compliance with the essential requirements and other relevant provisions of Directive 2...