38
Z-Wave specIfIcatIon
Notification Command Class
The device uses Notification Command Class to report different
events to the controller (“Lifeline” group).
Notification
Type
Event
Parameter
Status
In
endpoints
Power Man-
agement
[0x08]
Over-current
detected
[0x06/V3]
0xFF – enable
(non-change-
able)
Root, End-
point 1*,
Endpoint 2*
Power Man-
agement
[0x08]
Over-load de-
tected [0x08]
0xFF – enable
(non-change-
able)
Root, End-
point 1*,
Endpoint 2*
System
[0x09]
System hard-
ware failure with
manufacturer
proprietary fail-
ure code [0x03]
MP code:
0x01
[device
overheat]
0xFF – enable
(non-change-
able)
Root,
Endpoint 1*
Protection CC
Protection Command Class allows to prevent local or remote control
of the outputs.
Type State
Description
Hint
Local
0
Unprotected - The device is not
protected, and may be operated
normally via the user interface.
Inputs connected
with outputs.
Local
2
No operation possible – button can
not change relay state, any other
functionality is available (menu).
Inputs discon-
nected from
outputs.
RF
0
Unprotected - The device accept
and respond to all RF Commands.
Outputs can be
controlled via
Z-Wave.
RF
1
No RF control – command class ba-
sic and switch binary are rejected,
every other command class will be
handled.
Outputs cannot
be controlled via
Z-Wave.
Meter CC
Meter Type
Scale
Rate Type
Precision
Size
Electric
[0x01]
Electric_kWh
[0x00]
(default)
Import
[0x01]
2
4
Electric
[0x01]
Electric_W
[0x02]
Import
[0x01]
1
2
* only in Double Switch Mode