30
INSTRUCTIONS FOR CONNECTION TO NATURAL GAS
This BBQ has been configured for use with LPG from a gas cylinder. If you want to connect this BBQ to a
permanent Natural Gas supply, the following steps must be undertaken.
1/ Contact a licensed plumber or gas fitter and arrange a quote to convert this BBQ to Natural Gas, install any
pipework necessary to bring a natural gas supply to the installation area and commission the BBQ. All works
must be made by a licensed plumber or gas fitter in accordance with AS5601.1.
2/ Contact Pacific Gas & Heating Pty Ltd directly on Tel: 1300 793978 or email [email protected] to order
the gas conversion kit specific to your model and supply the name and license number of your chosen gas fitter.
3/ Obtain a certificate of compliance from your licensed gas fitter after installation is complete.
Natural Gas Conversion Procedure
Gas conversion must be conducted by a licensed plumber or gas fitter only.
•
Remove the main BBQ Burners.
•
Remove LPG injectors from all the main burner valves and replace with Natural Gas Injectors. The
natural gas injector size is 1.55 on the main burners.
•
Install BBQ Burners.
•
Set the side burner aeration shutter to 4mm open.
•
Remove the side burner valve and replace it with the side burner valve for Natural Gas.
•
Replace the side burner injector with the 1.8mm side burner injector for Natural Gas.
•
Remove 2.75kPa LPG hose and regulator assembly and replace with the stainless steel braided hose
and adaptor fitting to ½”BSP, and the ½”BSP Natural gas regulator with 1.0kPa operating pressure.
•
Apply the Natural Gas type label over the Propane label.
•
Permanently fix the BBQ to the floor in the installed position using the supplied fixing bracket, which
slots into the LPG Cylinder hole. This ensures the BBQ cannot move and strain the gas supply lines.
•
Leak test all connections.
•
Before leaving, test the operation of all burners on high and low to complete the commissioning process.
This involves removal of the knobs to access the screw adjustable low flame by pass to set a stable low
flame.
•
Instruct the consumer on correct use of the BBQ and the location of the gas supply isolation valve which
shall be closed after each use.
•
If the BBQ is supplied with a duplicate data label, apply this label in the immediate vicinity of the BBQ in
an easily accessible area.
Summary of Contents for MOMENTUM HS-18MA9401
Page 1: ......
Page 4: ...3 ...
Page 15: ...14 STEP 12 Assemble the injector bracket by screw D 2pcs as photo A and B shown A B ...