background image

Display for magnetic band

F7

Data: 13/01/16

F7_ing.doc

pag 6/12

Removing the battery from the instrument switches it off after a few seconds: at this point do not
move the sensor to avoid losing the correct displayed value. As soon as the battery is fitted, the
instrument switches on with the same value on the display which was present at the moment when
it was switched off. If the sensor has not be moved, the displayed value will be correct. In case the
sensor moved when the instrument was off, to re-establish the correct measure it is necessary to
repeat the adjustment process.

Display icons

1. 

Indicator of low battery, it is activated when is
it necessary to change the battery.

2. 

Indicator of inches measurement.

3. 

Indicator for origin 1 and 2

4. 

Indicator of relative displayed value.

5. 

Not used.

Error message

RX(U

RX(U

RX(U

RX(U

: the current displayed value passed the maximum value that can be visualized (possible

range: from –99999 to 99999).

Magnetic strip mounting

The magnetic strip P50 consists of a magnetized plastic ferrite strip with alternate magnetic poles
of 5 mm pitch, carried by a ferromagnetic steel strip. Mechanical protection of the plastic ferrite
strip is supplied by a non magnetic steel strip with thickness 0,2mm.

The magnetic strip is assembled by sticking it with a bi-adhesive tape. The surface has to be
smooth, clean and dry: is advisable to clean it with a degreasing product (isopropyl alcohol, ethyl
alcohol, solvents, etc). The magnetic strip has to be stuck holding the plastic ferrite side in the
direction of the sensor, which means the steel side leaned on the stand surface.  Fixed the
magnetic strip, to keep off damages due to abrasions or grazes of the plastic ferrite strip, is
advisable the appliance (always bi-adhesive) of the non magnetic protection strip.  The optimal
ambient temperature for stick the bi-adhesive tape is over 10°C.  The maximum adherence of the
tape works out after 48 hours (about) of the application and is kept between –10 and 80°C.

1

2
3

4

5

1,7

non magnetic steel strip 

(mechanical protection)

plastic ferrite strip

steel strip 
(plastic ferrite support)

10

sensor side

Summary of Contents for F7-

Page 1: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 1 12 USER S MANUAL AND MAINTENANCE DISPLAY FOR MAGNETIC BAND WITH BATTERY POWER SUPPLY TYPE F7 ...

Page 2: ...ow are some references to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatib...

Page 3: ...ing the corresponding button Also it is possible to set a preset value which can be activated by pressing the corresponding button The electronics are protected by a plastic housing which is robust shock resistant and self extinguishing Two versions of the F7 are available F7 E with external sensor F7 I with integrated sensor The display can be fixed quickly and easily using the two threaded holes...

Page 4: ...following VALUE ENTER RESET 0 Not active Not active Not active 1 mm inch conversion abs rel measurement Reset 2 Not active Not active Preset 3 Not active Not active Fast Preset 4 Not active Not active Change of origin 0 1 2 5 Not active Not active Offset 6 Not active Not active Fast Offset 7 Not active Not active Delayed reset after 3s 8 Not active Not active Delayed preset after 3s Delayed means ...

Page 5: ...pressing ENTER RESET 2 6W 2 6W 2 6W 2 6W appears and by pressing two times ENTER RESET it is possible to set directly the value to be displayed use buttons and confirm with ENTER RESET This function is useful if it is necessary to correct often the displayed value Count direction Set out the count direction of the display range allowed 0 or 1 Adjustment of displayed value After the installation of...

Page 6: ...ip mounting The magnetic strip P50 consists of a magnetized plastic ferrite strip with alternate magnetic poles of 5 mm pitch carried by a ferromagnetic steel strip Mechanical protection of the plastic ferrite strip is supplied by a non magnetic steel strip with thickness 0 2mm The magnetic strip is assembled by sticking it with a bi adhesive tape The surface has to be smooth clean and dry is advi...

Page 7: ...or mounting The sensor has be mounted according to the following draw and keeping the indicated tolerances For the optimal system functioning its is necessary that the distance between the sensor and the magnetic band is not over 1mm of the useful stroke 3 3 3 M A X 1 ...

Page 8: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 8 12 F7 E AM20 ...

Page 9: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 9 12 F7 I AM20 ...

Page 10: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 10 12 ...

Page 11: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 11 12 ...

Page 12: ...y IP67 sensor for F7 E only Sensor cable for F7 E only length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Sensor house for F7 E only alluminium black Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA ...

Reviews: