background image

Display for magnetic band

F20

Data: 13/01/16

file: F20_ing.doc 

pag 4/8

Sensor mounting

The sensor has be mounted according to the following draw, and keeping the indicated tolerances.
For the optimal system functioning its is necessary that the distance between the sensor and the magnetic
band is not over 1mm of  the useful stroke.

N.B. if the distance between the sensor and the magnetic band is over 1mm on the display appears
 

+,/

+,/

+,/

+,/

 ,and the measured value is wrong.

Programming

To step into the parameter programming press key PGM  fino a che apparirà sul display la scritta 

, now

press 2 times key RESET

/

ENTER

 and appear 4 zeroes, the first on the right is blinking, with keys   (digit

increase) and  

 (digit selection), set out password 

0273 

and confirm with RESET

/

ENTER

. . In case of

wrong set-out of password  it goes out of the programming.
The parameters that have to be set can be run with key   and in order of appearance they are:

0

0

0

0

value to be displayed for 100mm of sensor displacement,

+%

+%

+%

+%

number of decimal digits,

%.+

%.+

%.+

%.+

count direction,

//

//

//

//

keys opening mode

,/

,/

,/

,/

displacement of origin,

/

/

/

/

not used.

To enter into the modification of the selected parameter press two times 

RESET

 (one time displays only the

value) and with keys    and  

 set the wanted value to be confirmed with 

RESET

.

To go out of the programming press 

  .

0

0

0

0

Value to be displayed for 100 mm of sensor displacement

This parameter together with the following allows the programming of the value on the display for a certain
displacement of the sensor. It means that is necessary to set the value which has to be displayed
corresponding to a displacement of the sensor on the magnetic band of 100mm.
The Factory value is 

VISUAL

=100.0, which is the necessary value to read the displacement in millimetres with

decimal resolution.
The range allowed is from 0,000001 to 9999999 with setting of decimal point position that is, after
programming of the last digit on the left, pressing key 

  will blink the decimal pinpoint and with key   it can

be moved to the wanted position.  Confirm with RESET

/

ENTER

.

+%

+%

+%

+%

Number of decimal digits

It is the number of decimal digits to visualize on the display, range allowed from 0 to 5.
Example 1: for each 100 mm of sensor desplacement will have a displacement on the machine of 50, set

0

=

50 and 

+%

=

0.

Example 2: for each 100 mm of sensor desplacement on display has to appear 12,3. Set

0

= 000012,3 e  

+%

 

= 1.

±3°

±3°

±3°

MAX 1

MAGNETIC BAND

(

PLASTIC FERRITE SIDE  TOWARD THE

SENSOR

)

Summary of Contents for F20

Page 1: ...Display for magnetic band F20 Data 13 01 16 file F20_ing doc pag 1 8 USER S MANUAL AND MAINTENANCE DISPLAY FOR MAGNETIC BAND WITH INTERNAL BATTERY POWER SUPPLY TYPE F20 ...

Page 2: ...d to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with a soft clo...

Page 3: ...function for balancing of tool wear On the display all activated functions are showed by a symbol The keys enabling to recall the preset dimension and the absolute relative dimension switches may be inhibited in a very simply way On the display all activated functions are showed by a symbol The power supply is internal with 4 batteries type AA LR6 of 1 5V two year life The run down of battery is i...

Page 4: ...he selected parameter press two times RESET one time displays only the value and with keys and set the wanted value to be confirmed with RESET To go out of the programming press 0 0 0 0 Value to be displayed for 100 mm of sensor displacement This parameter together with the following allows the programming of the value on the display for a certain displacement of the sensor It means that is necess...

Page 5: ...the quote on the display has often be corrected Origin change quota correction for tool change with this function 5 different origins 1 2 3 4 5 are programmable and passes from an origin to the other wit key RESET ENTER Activating the function of origin change on the display appear two small arrows and the indication of the selected origin happens with the switching on of the origin indicators see...

Page 6: ...djusting quota is worth to zero instead of the preset is possible use reset setting value 1 on the first digit on the right of this way pressing RESET the value on the display will be zeroed Now that the instrument is adjusted its necessary re establish to the wanted value parameter to avoid Battery change The instrument is supplied with batteries type AA of 1 5V alkaline type which assures a func...

Page 7: ...lative quota mm indicator of mm Inch indicator of inchesi Deg Indicator of degrees Indicator of positive Offset indicates that the measure is corrected by a positive offset Indicator of negative Offset indicates that the measure is corrected by a negative offset Indicator of changing origins activated Errors messages 0 0 0 0 the current quota passed the maximum value that can be visualized from 99...

Page 8: ... wear adjustment Protection degree IP54 display IP67 sensor Sensor cable length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Sensor house alluminium black Maximum Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 30 90 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be address...