Adjusting of quota

After the assembling of instrument on the machine and setting of all parameters, to visualize on the display the
correct measure it is necessary to carry out the reset or preset of quota. Position the shaft in a point in which is
known exactly the correct measure that has to be visualized (ex. stroke checking) or measure the value in that
point of axis. Programme parameter 

//

 with value 3 in the first digit on the right and go out of the

programming. Now press 

RESET

 and it will appear Preset, press again 2 times 

RESET

 and set on the

display the correct measure to visualize, confirm with 

RESET

 and on the display appears the correct measure.

If the adjusting quota is worth to zero instead of the preset is possible use reset, setting value 1 on the first digit
on the right of 

//

, this way pressing 

RESET

 the value on the display will be zeroed.

Now that the instrument is adjusted its necessary re-establish to the wanted value parameter 

//

//

//

//

 to avoid

accidental reset/preset of quota.

Battery change

The instrument is supplied with 2 batteries type AA of 1,5V (alkaline type) which assures a functioning of about 1
year. When the loading level goes under a certain value, the indicator of flat-battery begins to blink in occasional
way and when it keeps switched on its necessary to change the batteries  within a month.
To enter into the battery-holder its necessary to take off the front-cover prising on the two hollows placed on a
side of the instrument. Take off the cover and take out the battery-holder and change the batteries paying
attention to the polarity indicated. Without batteries the instrument switches off: in this phase do not rotate the
hollow shaft to avoid  loosing of correct quota. As soon as the batteries are fitted inside, the instrument
switches on with the same value on the display as at the moment  of the switching off and if the shaft has not be
moved the value will be correct. In case the shaft is moved during the switching off, to re-establish the correct
measure its necessary to repeat the adjustment proceeding.

Meaning of the symbols on the display

1.

Indicator of flat battery: begins to blink when the level of loading goes under a certain value and when it
keeps switched on its necessary to change the batteries within 1 month.

2.

Indicator of absolute quota

3.

Indicator of relative quota

4

.

Indicator of mm

5.

Indicator of inches

6.

Indicator of degrees

7.

Indicator of positive Offset: indicates that the measure is corrected by a positive offset

8.

Indicator of negative Offset: indicates that the measure is corrected by a negative offset

9.

Indicator of values changing: it blinks during the programming phase

10.

Indicator of origins: indicates that the origin changing mode is opened

11.

Indicator for origin 1

12.

Indicator for origin 2

Erros messages

overfl

: the current quota passed the maximum value that can be visualized (from –999999 to 999999);

error1

: its necessary to adjust again the quota;

notape

: inner failure, contact the technical assistance.

1

2

7 8

10

3

9
6
5
4

11

12

Summary of Contents for EP25L

Page 1: ...Hollow shaft display EP25L Date 13 01 16 file EP25L_ing doc pag 1 6 USER S MANUAL AND MAINTENANCE ELECTRONIC HOLLOW SHAFT DISPLAY BATTERY SUPPLIED TYPE EP25L ...

Page 2: ...to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with a soft cloth...

Page 3: ...arings The power supply is internal with 2 batteries type AA of 1 5V one year life The run down of battery is indicated with occasional blinking 1 month before the complete flat the indication remains on the battery has to be changed in very easy way and without loosing quota while the shaft is standing Programming To step into the parameter programming press key and on the display appears now pre...

Page 4: ...small arrows and the indication of the selected origin happens with the switching on of the origin indicators see paragraph meaning of symbols After setting 4 in the first digit on the right of will appear PrS0 and pressing 2 times RESET has to be set the value to be read in this position of shaft for origin 0 confirm with RESET It will appear PrS1 which is the value to be read for origin 1 in the...

Page 5: ... to take off the front cover prising on the two hollows placed on a side of the instrument Take off the cover and take out the battery holder and change the batteries paying attention to the polarity indicated Without batteries the instrument switches off in this phase do not rotate the hollow shaft to avoid loosing of correct quota As soon as the batteries are fitted inside the instrument switche...

Page 6: ...t origins for tool changing tool wear adjustment Power supply 2 alkaline batteries 1 5V type AA Weight 370g Protection degree IP54 Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 341 ...

Reviews: