Hollow shaft display
EP25L
Date: 13/01/16
file: EP25L_ing.doc
pag 4/6
Count direction
%.+
%.+
%.+
%.+
Set out the count direction of the display, range allowed 0 or 1.
Setting 0 the value on the display increases, turning the hollow shaft clockwise.
Setting 1 the value on the display decreases, turning the hollow shaft clockwise.
Keys opening mode
//
//
//
//
This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the right stands for
setting of key
RESET
, the digit in the middle stands for key while the last digit on the left stand for key
.
The values allowed are the following:
VALUE
KEY
KEY
KEY
RESET
0
Not open
Not open
Not open
1
Function
ABS
/
REL
Conversion mm/inch
Reset
2
Not open
Display in degrees
Preset
3
Not open
Not open
Fast Preset
4
Not open
Not open
Change of origin 0,1,2
Reset:
function
of reset of quota, pressing on key
RESET
the quota is zero-set .
Preset:
function of preset of quota, pressing on key
RESET
the quota on the display became the same of the
one set in parameter Preset. The setting of Preset value appears immediately after parameter
//
//
//
//
(if
chose value 2).
Fast
Preset:
the fast setting of the quota on the display, pressing on key
RESET
appears Preset and pressing
still 2 times
RESET
is possible to set the value directly (use keys
and confirm with
RESET
). This
function is useful when the quote on the display has often be corrected.
Origin change
(quota correction for tool change): with this function 3 different origins (0,1,2) are
programmable and passes from an origin to the other wit key
RESET
. Activating the function of origin change
on the display appear two small arrows and the indication of the selected origin happens with the switching
on of the origin indicators (see paragraph meaning of symbols ). After setting 4 in the first digit on the right of
//
, will appear PrS0 and pressing 2 times
RESET
has to be set the value to be read in this position of
shaft for origin 0, confirm with
RESET
. It will appear PrS1 which is the value to be read for origin 1 in the
present position of shaft: set the correct value and confirm with
RESET
. It will appears PrS2 which is the value
to be read for origin 2 in the present position of shaft: set the correct value and confirm with
RESET
. It means
PrS0, PrS1, PrS2 are references for the calibration, in a certain position of the shaft, in three different origins.
Function
ABS
/
REL
:
Enables the pass from absolute to relative value, pressing key
zero-set temporary the
value to allow a relative shifting. On the display switches on indicator REL to indicate that the current quote is
relative to the zero-point just created. Pressing still key
reappears the absolute value and on the display
switches on the indicator ABS.
Conversion mm/inch:
Pressing key converts the measure from millimetre to inches and back with
indication of inch/mm on the display and a decimal number more then for millimetres. By choosing 5
decimals for millimetres the conversion in inches is not allowed.
Visualization in degrees:
Pressing on key on the display appears Deg to indicate the visualization of
measure in degrees.
Origin displacement
,/
,/
,/
,/
This parameter is added or subtracted from the current quota to correct the value showed on the display, for
example following wear or changing of tool. Setting a positive value on display appears the current quota added
to this value.
Set zero to exclude the offset function (manufacturer’s value).