Hollow shaft display

EP25L

Date: 13/01/16

file: EP25L_ing.doc

pag 4/6

Count direction  

%.+

%.+

%.+

%.+

Set out the count direction of the display, range allowed 0 or 1.
Setting 0 the value on the display increases, turning the hollow shaft clockwise.
Setting 1 the value on the display decreases, turning the hollow shaft clockwise.

Keys opening mode

 

//

//

//

//

This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the right stands for
setting of key 

RESET

, the digit in the middle stands for key   while the last digit on the left stand for key 

 .

The values allowed are the following:

VALUE

KEY   

KEY   

KEY  

RESET

0

Not open

Not open

Not open

1

Function

 ABS

/

REL

Conversion mm/inch

Reset

2

Not open

Display  in degrees

Preset

3

Not open

Not open

Fast Preset

4

Not open

Not open

Change of origin 0,1,2

Reset: 

function

 

of reset of quota, pressing on key 

RESET

 the quota is zero-set .

Preset:

 function of preset of quota, pressing on key 

RESET

 the quota on the display became the same of the

one set in parameter Preset. The setting of Preset value appears immediately after parameter 

//

//

//

//

 (if

chose value 2).

Fast

 

Preset: 

the fast setting of the quota on the display, pressing on key 

RESET

 appears Preset and pressing

still 2 times 

RESET

 is possible to set the value directly (use keys        

  and confirm with 

RESET

). This

function  is useful when the quote on the display has often be corrected.

Origin change 

(quota correction for tool change): with this function 3 different origins (0,1,2) are

programmable  and passes from an origin to the other wit key 

RESET

. Activating the function of origin change

on the display appear two small arrows  and the indication of the selected origin  happens with the switching
on of the origin indicators (see paragraph meaning of symbols ). After setting 4 in the first digit on the right of

//

, will appear PrS0 and pressing 2 times 

RESET

 has to be set the value to be read in this position of

shaft for origin 0, confirm with 

RESET

. It will appear PrS1 which is the value to be read for origin 1 in the

present position of shaft: set the correct value and confirm with 

RESET

. It will appears PrS2  which is the value

to be read for origin 2 in the present position of shaft: set the correct value and confirm with 

RESET

. It means

PrS0, PrS1, PrS2 are references for the calibration, in a certain position of the shaft, in three different origins.

Function 

ABS

/

REL

:

 

Enables the pass from absolute to relative value, pressing key 

  zero-set temporary the

value to allow a relative shifting. On the display switches on indicator REL to indicate that the  current quote is
relative to the zero-point just created. Pressing still key 

 reappears the absolute value and on the display

switches on the indicator ABS.

Conversion mm/inch:

 Pressing key  converts the measure from millimetre to inches and back with

indication of inch/mm on the display and a decimal number more then for millimetres.  By choosing 5
decimals for millimetres the conversion in inches is not allowed.

Visualization in degrees: 

Pressing on key    on the display appears Deg to indicate the visualization of

measure in degrees.

Origin displacement    

,/

,/

,/

,/

This parameter is added or subtracted from the current quota to correct the value showed on the display, for
example following wear or changing of tool. Setting a positive value on display appears the current quota added
to this value.
Set zero to exclude the offset function (manufacturer’s value).
The offset is not available if the function of tool-change is selected.

Summary of Contents for EP25L

Page 1: ...Hollow shaft display EP25L Date 13 01 16 file EP25L_ing doc pag 1 6 USER S MANUAL AND MAINTENANCE ELECTRONIC HOLLOW SHAFT DISPLAY BATTERY SUPPLIED TYPE EP25L ...

Page 2: ...to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with a soft cloth...

Page 3: ...arings The power supply is internal with 2 batteries type AA of 1 5V one year life The run down of battery is indicated with occasional blinking 1 month before the complete flat the indication remains on the battery has to be changed in very easy way and without loosing quota while the shaft is standing Programming To step into the parameter programming press key and on the display appears now pre...

Page 4: ...small arrows and the indication of the selected origin happens with the switching on of the origin indicators see paragraph meaning of symbols After setting 4 in the first digit on the right of will appear PrS0 and pressing 2 times RESET has to be set the value to be read in this position of shaft for origin 0 confirm with RESET It will appear PrS1 which is the value to be read for origin 1 in the...

Page 5: ... to take off the front cover prising on the two hollows placed on a side of the instrument Take off the cover and take out the battery holder and change the batteries paying attention to the polarity indicated Without batteries the instrument switches off in this phase do not rotate the hollow shaft to avoid loosing of correct quota As soon as the batteries are fitted inside the instrument switche...

Page 6: ...t origins for tool changing tool wear adjustment Power supply 2 alkaline batteries 1 5V type AA Weight 370g Protection degree IP54 Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 341 ...

Reviews: