31
pin-out Db 15 female
POWER SUPPLY UNIT TECHNICAL SPECIfICATIONS:
Specification
Value
Unit
v a.c.
hz
W
°C
Kg
230 +/-10%
50-60
80
0-40
0,6
mains supply voltage
mains supply frequency
Rated power
operating temperature
power supply unit weight
MAINTENANCE
the tool signals when 1,000,000 cycles have been reached (the front light flashes in
rotation) and the need for an inspection which must be carried out by fiam technical
assistance.
if you do not wish to proceed with the inspection, the signal can be reset by following
the instructions given in the table on page 12, function no. 6.
if this option is taken, fiam declines all responsibility for subsequent damage or mal-
function.
for the system to work correctly we recommend the following rules be observed:
minimum pause between two successive tightening cycles = 3 times the tightening
time (e.g. 1 sec. tightening time, 3 secs. minimum pause between successive tight-
ening cycles).