17 / 18
Connection information
Input terminal voltage
24 V
DC
to 66 V
DC
from the telephone connection
Power supply current
28 mA
DC
to 100 mA
DC
Call signal voltage
35 V
AC
to 90 V
AC
(23…54 Hz)
Call signal impedance
Larger 5.5 kW at 25 Hz and 30…90 V
AC
Larger 4.0 kW at 50 Hz and 30…90 V
AC
Dialling method
Dual-tone multi-frequency signalling (DTMF)
Pip-tone dialling; pip-tone interval ratio 1.5:1 or 2:1.
Connecting terminals
Max. 2.5 mm
2
Relay contact points
Max. 30V
AC
Max. 60V
DC
Max. 1 A
eff
Max. 30 W
Tamper contact
Max. 30V
AC
Max. 60V
DC
Max. 30 W
Dimensions
With casing
Built-in unit
Material
VA
Front Panel VA
Height x Breadth x Depth Approx. 205 x 110 x 60 mm Approx. 205 x 110 x 55 mm
Weight
Approx. 1.2 kg
Approx. 0,65 kg
Scanner
Metal scanner made of VA with integrated red LED
Environmental conditions With casing
Built-in unit
Protection type:
IP 66 as per EN60529
IP 66 (frontal)
Operating temperature:
-40°C to +60°C
Storage temperature:
-40°C to +70°C
Other features
Call volume
- 7 levels and silent
- Maximum approx. 80 dB(A) at a distance of 1 m at 50 VAC / 50Hz
Call melodies
9 melodies
Minimum call duration
until automatically
engaged
≥
800 ms without interruption (call diversion not permitted)
Call pause duration for
call pause bypass
2 … 6 s
Speaker
- Maximum volume approx. 68 dB(A) at a distance of 1 m
- Volume 7 levels
Directives and regulations
Conformity with the
following directives and
regulations:
- R&TTE directive 1999/5 EC
- Low voltage directive 73/23/EEC
- EMC directive 89/336/EEC for residential and industrial zones