background image

The equipment described in this Operating instructions manual is a flame proof device for use in
hazardous areas of Group II and Zones 1 and 2.

The following warnings and safety notes must be especially observed:

1. The device is designed in compliance with insulation class I and may be connected and

operated at the mandatory voltage only. A proper connection must be especially observed.

2. Waiting time until opening 15 sec.

3. Take care not to damage the housing.

4. The device may be operated under the mandatory ambient conditions only (refer to Technical

specifications). Bad ambient conditions may lead to damage to the device. Such bad ambient
conditions are:

• too high continuous air humidity

• inflammable gases, vapours, solvents, dusts

• too low or too high ambient temperatures

5. The mandatory operational position of the device must be considered.

6. The device is meant for use indoors or outdoors.

7. During operation of the device the legal and professional regulations, the safety regulations,

and the electrical rules and regulations regarding connection and operation with line voltage
must be observed. Connection and commissioning may be done by an educated professional
only.

8. The device may be opened by educated professional personnel only. During the process of

opening covers or removing parts live parts may be exposed.

9. If repairs or a replacement of parts include opening the device, the device must be separated

from all power sources prior to such work.

10. In case of repairs only original spare parts may be used. Any other spare parts may lead to

personal injury and/or equipment damage.

11. If it is unavoidable to repair the powered device, this may be done by an educated professional

only. 

12. Continuous subjection to signalling and/or too small distance to the signalling source may cause

hearing damage.

User information

Änderungen vorbehalten
Subject to change without notice

FHF Funke + Huster Fernsig GmbH

Eintrachtstrasse 95 · 42551 Velbert

Phone +49 / 20 51 / 270-0 · Fax +49 / 20 51 / 270-377 

http://www.fhf.de · e-mail: [email protected] 

Summary of Contents for 5842/2

Page 1: ...n und Hin weise zum Anschalten an das Telefonnetz zu beachten Ruf wechselspannung an Klemmen Lb und W Note Prior to installing the device these operating instructions must be read carefully In case of any damage and liabilities the latest version of the General terms of delivery of products and services in the electric industry is authorita tive Notes on use The explosion proof secondaray sonder i...

Page 2: ...nd W Rufwechselspannung 32 VAC bis 75 VAC 23 Hz bis 54 Hz überlagerte Speisespannung 0 VDC bis 63 VDC Eingangsimpedanz bei 25 Hz Z 8 kΩ bei 50 Hz Z 4 kΩ Stromstärke IK 울 3 A Potentialausgleich Anschluss innen am Gehäuse Schutzklasse I Akustischer Signalgeber Lautsprecher Akustisches Signal 3 Tonruf Tonfolge 800 Hz 1067 Hz 1333 Hz 2 Tonruf ca 931 Hz ca 1253 Hz Tonfolgefrequenz 4 unterschiedliche Ei...

Page 3: ... 2 single core and fine strand Operation position any wall mount ceiling mount Protection category IP 66 Explosion category II 2 G EEx em ib IIC T6 Certificate of conformity DMT 99 ATEX E 095 CE label yes according to EMC Law 11 92 Ambient operation temperature 20 C to 40 C Storage temperature 40 C to 75 C Transport temperature 40 C to 75 C Relative humidity up to max 90 Telephone connection Termi...

Page 4: ...4 ...

Page 5: ... Gerätes ist zu berücksichtigen 6 Das Gerät ist für den Betrieb in Räumen oder im Freien bestimmt 7 Bei Betrieb des Gerätes sind die gesetzlichen und gewerblichen Vorschriften Unfallverhütungsvor schriften sowie elektrische Bestimmungen und Vorschriften zum Anschluss und Betrieb an Netzspannung zu beachten Der Anschluss und die Inbetriebnahme darf nur durch einen unter wiesenen Fachmann erfolgen 8...

Page 6: ... of the device the legal and professional regulations the safety regulations and the electrical rules and regulations regarding connection and operation with line voltage must be observed Connection and commissioning may be done by an educated professional only 8 The device may be opened by educated professional personnel only During the process of opening covers or removing parts live parts may b...

Reviews: