background image

OPTION 

OPTION 

ON

Door closes automatically after waiting the a.c. time.

OFF

Door does not close automatically.

OPTION 

ON

Alternative button stops and invert at close. Disable stop opening.

OFF

Alternative button stops.

OPTION 

ON

Invert drive direction.

OFF

Normal drive direction.

OPTION 5 - Pneumatic Band with Stop Options

ON

Input Cseg1 works like security band, stopping opening and closing.

OFF

Input Cseg1 works like security band, stopping the closing and stop & 
inverts 2 sec. in the opening.

OPTION 6 - Flashing Light

ON

Flashing

OFF

Fixed

OPTION 7 - Buffer Closing

ON

Drive reduce it’s speed at the end of opening & closing.

OFF

No buffer.

OPTION 8 - Enconder Yes/No

ON

Enable encoder input.

OFF

Disable encoder input.

1 - Garage Doors / Sliding Gate 

ON

Garage.

OFF

Sliding.

2 - Automatic Closing

3 - Door Stop & Inverts and Disable Stop Opening

4 - Drive Direction

OPTIONS SELECTOR

( EURO220M1 )

Instruction Manual

The maneuvers are executed through the START button (Test button on the motherboard, or Alternative switch terminals, or by radio card). 
The maneuvers ends for one of the following conditions: activation of the corresponding end switchs orby the end of operating time. 
If during the opening operation is given an order, the action is stoped and do not run the closing. 
Stop button activation causes immediate stop of the maneuver, requiring an order for the resumption of it. 
Activation os safety switch input during closing, inverts it and goes to open position. 
Garage light is activated during 0.5 sec. before starting the opening operation and is turned off 3 minutes after it. 
Courtesy light at the opening (if allowed) flashes slowly, and on closing flashes quickly. In open position courtesy light is ON. 
Drive power regulation selected in R. FORCE, it will be applied after 2 sec. Of the maneuvre.

In order to program functions the control panel should be in a stable state with the door closed.
Option number 3 I3  must be turned OFF. If we want buffer closing I7 must be turned ON and if we have an encoder DIP switch number 8 I8 must be turned ON too. 
Push button PROG TIEMPOS   for 1,5 secs. The red LED will light up indicating that the panel is ready for time programming. Now we can proceed. In order to stop 
programming press button PROG for 1,5 secs again with the door in 'resting' position; the process requires that a full opening and closing cycle is completed.

Programming times process

1) The door must be closed. Activate as described above. The red LED lights up.
2) Push “START" button to open the door.
Pushing “START" again will stop the door and will memorize the time of opening. If opening is finalized by limit switch open (FCA), the programme will memorise times + 4 
sec.
3) Once the door is open, the closing time will be memorized automatically until the closing operation has begun.
4) Push"P.ALT" button to close the door.

I7 OFF - 

Pushing “START" again will stop the door and memorize the closing time. If closing is finalized by limit switch (FCC), the programme will memorise 

times + 4 sec.

I7 ON - 

Pushing “START” button again, drive reduce the speed (buffer closing), and pressing it again, the manoeuvre will stop and closing time, and buffer 

closing will be memorized. If the manouvre is finalized by limit switch open (FCA), the programme will memorise times + 4 sec.
5) Upon completing a full cycle of the door programming will be automatically finalized.

The maximum memorization time is 2 minutes, if you wait more, this limit will be memorized.

OPERATING INSTRUCTIONS

DIGITAL PROGRAMMING 

of open, close & automatic close.

GB

CANCELLATION OF ALL CODES

- Here we have to reset the memory.
- Press PROG/RES for 3,5 seconds.
- After 1,5 seconds one acoustic signal will be heard indicating that you have entered the 
code memorization mode, maintain the button pressed. 
- After 3,5 seconds you will hear a series of acoustic signals.
- Stop pressing the button. 
- The receptor will have cancelled all codes.
- The System stays in memorization mode, ready to receive new codes (see system a))

FIRMWARE

CODE MEMORITZATION

Manual memoritzation

- Press button PROG/RES for 1,5 sec. 
- On hearing the acoustic signal stop pressing as the receptor will be logged onto the memorizing code sequence. 
- From this moment received codes will be memorized.
- In order to memorize push any button on the transmitter. 
- The memorization of a code is confirmed with one acoustic signal.
- The receiver will exit automatic memorization code sequencing after 10 seconds from the last code input. This will be indicated with two acoustic signals. Emergency exist 
of the automatic memorization code sequencing can be done by pushing the special function button on one of the transmitters which is being coded (within 10 seconds). 

Semiautomatic memorization

- In order to activate this system must have memorized at least one code into the receiver.
- Push the special function button on one of the transmitters which have been codified. 
- On hearing one acoustic signal or when PROG led will turned ON, stop pushing and the receiver will have entered into code memorization sequence.
- From that moment.. follow the steps of manual memoritzation.

Summary of Contents for E102

Page 1: ...horoughly read this manual that is an integral part of this Kit FGMATIC declines any responsa bilit in the event curret stadards in the country of installation are not comlplied with ATTENTION Avant d...

Page 2: ...poso el proceso de programaci n se cierra autom ticamente al finalizar un ciclo completo de la puerta Proceso de programaci n de los tiempos 1 Partiendo de la posici n de puerta cerrada activaremos el...

Page 3: ...GULACIONES REGULACI N FUERZA MOTOR Regula la fuerza del motor Girar a la IZQUIERDA para disminuir y a la DERECHA para augmentar Regulaci n Paro Suave REGULACI N DE LA VELOCIDAD FINAL I7 ON MOTOR M 14...

Page 4: ...bed above The red LED lights up 2 Push START button to open the door Pushing START again will stop the door and will memorize the time of opening If opening is finalized by limit switch open FCA the p...

Page 5: ...TANDARD CONTROL PANEL SET UP BRIDGE SELECTORS TERMINAL DESCRIPTION 220V 19 20 LIMIT SWITCH LIMIT SWITCH OPEN CLOSE 9 10 8 REGULATIONS STRENGTH MOTOR REGULATION Regulation the strength of motor Rotate...

Page 6: ...n appuyant de nouveau sur le poussoir alternatif START on va arr ter la man uvre et le temps de fermeture sera m moris Si se finalise la man uvre de fermeture par activation du fin de course de fermet...

Page 7: ...PTION BORNES 220V 19 20 R GLAGES R GLAGE DE FORCE DU MOTEUR R gle la force du moteur Tournez a DROITE pour augmenter et a GAUCHE pour diminuer R glage arr t doux R glage de la vitesse finale I7 ON MOT...

Page 8: ...termina automaticamente ao finalizar um ciclo completo da porta Processo de programa o dos tempos 1 Na posi o de porta fechada activar o modo de programa o dos tempos conforme a forma indicada acima o...

Page 9: ...20 REGULA ES REGULA O FOR A MOTOR Regula a for a do motor Girar ESQUERDA para diminuir e DIREITA para aumentar Regula o Par Suave REGULA O DA VELOCIDADE FINAL I7 ON MOTOR M 14 15 13 COMMON P PEAT P S...

Page 10: ...ont conformer la norme UNI EN 12453 EN 12445 Nossos produtos se instalado por pessoal qualificado capaz de avaliar risco cumprir UNI EN 12453 EN 12445 UNI EN I dati e le immagini sono puramente indica...

Reviews: