P119 User Guide HWD-2102 REVISED MARCH 2020
6
2
1
0
9
8
7
6
5
4
3
S3 TH
TEMPERATURE SETTING DIAL
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
S1
PORTION
S2
PORTION CONTROL [TIMER] SETTING DIALS
TABLE OF TECHNICAL DATA
TEMPERATURE
PORTION
Portion size is controlled by dispense time
Top Dial
Center Dial Timer
Bottom Dial Timer
SW3=Temperature
SW2 Time seconds
SW1=Time-10s
Celsius scale used
Volume setting -
1
sec increments
Volume setting -
10
sec increments
0 = 78C (172°F)
0=1second (Default to 40ml)
0=add 0 seconds
1 = 80 C (176°F)
1=1 sec. or 40ml
1=add 10 seconds
2 = 82 C (180°F)
2=2 sec. or 80ml
2=add 20 seconds
3 = 84 C (183°F)
3=3 sec. or 120ml
3=add 30 seconds
4 = 86 C (187°F)
4=4 sec. or 160ml
4 {Inactive position}
5 = 88 C (190°F)
5=5sec. or 200ml
5 {Inactive position}
6 = 90 C (194°F)
6=6 sec. or 240ml
6 {Inactive position}
7 = 92 C (198°F)
7=7 sec. or 280ml
7 {Inactive position}
8 = 94 C (201°F)
8=8 sec. or 320ml
8 {Inactive position}
9 = 96 C (205°F)
9=9 sec. or 360ml
9 {Inactive position}
Factory set at maximum—
96°C/205°F
Factory calibrated setting:
200ml/6.8oz set at 5sec at 96°C/205°F
Settings in table may vary and are given for the conditions below:
Mains 0.34MPa/50PSI and Flow Rate:5.7lpm/1½ gpm at 55°F/13°C
Correction for altitude table
Portion size setting:
Flow is 40ml per second and is proportional to mains pressure.
The two timer dials are additive and control flow for 1 to 30 seconds
Dispense volume at 1-30 seconds is approximately 40-1200ml
(1.3-40.6 fluid ounces)
Portion time =
SW1 (0, 10, 20, 30) + SW2 (0-9)
Min Time = 1 second- Will default to 40ml if SW1 & SW2 are set to 0
Max Time is 30 Seconds
Range: 1 sec to 30 seconds minimum to maximum single dispense
is 40ml/1.4 ounces to 1200ml/40.5 ounces
50psi/3.4bar/0.344MPa
Mains Pressure: 45-75 psig (0.31-0.517 mPa)
(0.34MPa/50PSI preferred
Altitude
Boiling Point
(ft)
(m)
(
o
f)
(
o
c)
-250
-76
212.5 100.3
0
0
212
100
500
152
211
99.5
1000
305
210.1 98.9
1500
457
209.1 98.4
2000
610
208.1 97.8
2500
762
207.2 97.3
3000
914
206.2 96.8
3500
1067
205.3 96.3
4000
1219
204.3 95.7
4500
1372
203.4 95.2
5000
1524
202.4 94.7
5500
1676
201.5 94.2
6000
1829
200.6 93.6
6500
1981
199.6 93.1
7000
2134
198.7 92.6
Corrections to compensate for
boiling point changes due to
elevation. Allow 5-10%
IMPORTANT When Changing Settings, after adjusting dials, or following reassembly and plugging in:
1) Switch machine “OFF” for about ten seconds
2) Toggle back “ON” (Control Reset) .