Fetco HWD-2102 User Manual Download Page 5

Go to fetco.com for the latest version of all information                                     

 

P119  User Guide HWD-2102      REVISED MARCH 2020

 

 

 

Adjusting Temperature and Dispense Portion 

1)Open the cover panel 

2) Accessing control settings  

To access controls 

1) Remove silicone tap guard first 

2) Remove lower face panel 

3) Upper face panel next, 

4) Top panel last 

 

Access the temperature and dispense portion with three rotary switches 

 

Dials are marked 

 S3

 TH 

(temperature

)   

 

S2

 time(

x

) 1  }  (

portion

 

S1

 time(

x

) 10 

 

To access rotary switches for adjusting  

  Unplug the machine before disassembly or changing settings 

-Turn off power 

-Pull off silicone tap guard  

-Remove all screws and panels to access control board for adjustments. 

-Temperature and portion dials are located under upper face panel (#3) 

See below for settings & make adjustment(s) 

 

Reinstall and tighten all screws before power-up 

Do not operate until all covers and screws in place.  

NOTICE: Reinstall ribbon connector into CN-3 if it is detached-SEE BELOW 

 

IMPORTANT When Changing Settings

After adjusting dials, or following reassembly and plugging in. 

1)

Switch machine “OFF” for about ten seconds  

2)

 Toggle back “ON” (Control Reset) 

 

Reinstall covers 

-Reverse steps 1-4 (above) 

 

3) To set water portion and temperature controls 

Actual portions and temperatures shown are estimated and are influenced by mains flow rate and temperature 

Upper Dial (

Marked: S3

Set temperature 

Base temperature begins at 78°C/172°F, 

and increments in two degree Celsius units. 

Add two degrees for each dial position 

numerical value in degrees Celsius (°C) to 

78° base to a maximum of 96°C/205°F 

Unit is factory set at 

96°C/205°F. 

 

 

 

 

Lower Dials 

(Marked S1 &S2 )

 

Set dispense volume

 

The two lower dials control the hot water volume to 

be delivered by setting the dispense time in 

seconds. 

The timer dials are additive and control flow for 1 to 

30 seconds or approximately 40-1200ml (1.3-40.6 

fluid ounces.) 

36-42 ml/1.2-1.4oz is dispensed in 1 second. 

 

Actual volume delivered is affected by flow rate (the 

supply water line pressure).   Lower water pressure 

or pressure drops may lower flow rate.   Higher 

pressure will increase flow rate

Unit is factory set at 

5 seconds 

200ml/6.8oz

.

 

 

 

 

 

 

 

 

Dial Settings for 

Temperature

 

Upper dial 

Temperature 

Setting

 

Deg. C

 

Deg. F

 

78 

172 

80 

176 

82 

180 

84 

183 

86 

187 

88 

190 

90 

194 

92 

197 

94 

201 

96 

205 

Dial Settings for 

 

Dispense Volume

 

Bottom  Top  Sec 

ml 

oz 

0

+

  0

=

 

40  1.4 

0

+

  1

=

 

40  1.4 

0

+

  5

=

 

200  6.8 

0

+

  6

=

 

240  8.1 

1

+

  5

=

 

15 

600  20.3 

2

+

  5

=

 

25 

1000  33.8 

3

+

  0

=

 

30 

1200  40.6 

Volumes above are an example at typical 

0.34MPa/50PSI water pressure. 

 

Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice 

 

1) 

TO REMOVE: 

Pull silicone 

tap guard 

down 

S3

   T

               

TE

M

PE

RAT

URE

 S

ET

TI

NG

 DI

AL

 

 

S1

 P

OR

TI

ON

  

S2

 

               

PP

OR

TI

ON 

CO

NT

RO

L [

TI

ME

R]

 SE

TT

IN

G DI

AL

S

 

CN3 

Reinstall ribbon connector into  

CN-3 if detached.   

This connection is the dispense switch 

Summary of Contents for HWD-2102

Page 1: ...000 Fax 847 719 3001 Email sales fetco com techsupport fetco com PATENTS WWW fetco com patents P11919 REVISED March 2020 User s Guide Hot Water Dispenser HWD_2102 With Portion Control Domestic and Export Version Table of Contents Operator And User Sections Operating Instructions 3 Operating Principles 4 Adjusting Temperature and Dispense Portion 5 Error Messages 7 Cleaning Maintenance 8 Profession...

Page 2: ...Power Plug Configurations Please see wiring diagrams located in back pages for installation notes Specifications and Requirements Capacities Measurements Brewer Height Width Depth Empty Weight Filled Weight Hot Water Tank Capacity Shipping Weight Shipping Dimensions HWD 2102 19 inch 483 mm 8inch 203 mm 16 inch 410 mm 19 lb 8 6kg 36 lb 16 3kg 1 8 gal 6 9 liter 25lb 11 3kg 26 X 13 X 17in 660 X 330 X...

Page 3: ...d Multiple dispenses are possible when the UNLOCK DISPENSE light pad is steady and red colored Reactivate next dispense portion by retouching pad Finger must be on pad to dispense To dispense with PORTION CONTROL Touch and Hold 1 Press and hold UNLOCK DISPENSE pad for 3 seconds to unlock and activate dispensing system Border of UNLOCK DISPENSE pad will rapidly strobe signaling activation 2 Remove ...

Page 4: ...ing ON activation Hot water is drawn from the faucet the fill valve cycles on and off to replenish the hot water tank When dispensing water at a rate that exceeds the unit s capacity to heat the ready light will go off to show that the selected preset temperature is not available Always observe the READY lamp When the green READY lamp is lit proper dispense temperature is enabled When heating or r...

Page 5: ...8 C 172 F and increments in two degree Celsius units Add two degrees for each dial position numerical value in degrees Celsius C to 78 base to a maximum of 96 C 205 F Unit is factory set at 96 C 205 F Lower Dials Marked S1 S2 Set dispense volume The two lower dials control the hot water volume to be delivered by setting the dispense time in seconds The timer dials are additive and control flow for...

Page 6: ...Settings in table may vary and are given for the conditions below Mains 0 34MPa 50PSI and Flow Rate 5 7lpm 1 gpm at 55 F 13 C Correction for altitude table Portion size setting Flow is 40ml per second and is proportional to mains pressure The two timer dials are additive and control flow for 1 to 30 seconds Dispense volume at 1 30 seconds is approximately 40 1200ml 1 3 40 6 fluid ounces Portion ti...

Page 7: ...ith suggested setting for the operator at higher elevations BLINK BLINK ON Heater open If the heater is on and Tank temperature is not increasing according to software logic and the tank temperature 92C HEATER OPEN This means that the power board or that the heater control triac is sending power to the heater but the heating element is faulty or damaged OPEN circuit Fault is with the damaged heati...

Page 8: ...fore turning on power 5 No user serviceable parts refer to qualified service technician for repair and adjustments 6 Dangerous high voltage and high temperatures inside 7 Unplug machine before disassembly or changing settings 8 Operation requirements and maintenance for commercial cooking appliances differ from household appliances 9 Operators must be trained for this equipment and must understand...

Page 9: ...al service connection is compatible with the specifications on the equipment serial number label Make sure the electrical service will match the current draw of the equipment 11 Access the terminal block for electrical connection in the front of the unit by following the illustration above 12 A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near ...

Page 10: ...ice area is restricted to persons having safety hygiene knowledge and practical experience of the coffee brewer This appliance must be installed in locations where it can be overseen by trained personnel 2 For proper operation this appliance must be installed indoors where the temperature is between 10 C 50 F to 35 C 95 F Drain and remove al liquid from equipment and lines if exposed to freezing t...

Page 11: ...0 WASHER 6 SCREW INTL TOOTH LOCKWASHER 6 4 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 7 1 1051 00016 00 BOARD TRIAC DRIVE WITH RC FILTER 8 1 1023 00166 00 FITTING COLD WATER INLET GROMMET DESIGN 9 3 1024 00050 00 GROMMET SILICONE 11 4mm ID 10 1 1023 00167 00 FITTING BREW GROMMET DESIGN 11 2 1024 00053 00 LEVEL AND TEMP PROBE GROMMET 12 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 13 1...

Page 12: ...Go to fetco com for the latest version of all information P119 User Guide HWD 2102 REVISED MARCH 2020 12 ...

Page 13: ...1029 00017 00 FAUCET SILICONE HWD 2100 22 1 1023 00153 00 TOP COVER HWD 2102 23 1 1102 00250 00 ASSEMBLY FRONT PANEL MEMBRANE SWITCH HWD 2102 24 1 1023 00154 00 BOTTOM BASE HWD 2102 25 1 1023 00152 00 FRONT PANEL BOTTOM HWD 2102 26 4 1023 00136 00 LEG HWD 2100 27 1 1102 00156 00 DRIP TRAY ASSEMBLY HWD 2100 28 1 1024 00041 00 PUSH IN GROMMET 1 4 ID 7 16 PANEL HOLE 29 10 1082 00058 00 SCREW 8 32 X 5...

Page 14: ...Go to fetco com for the latest version of all information P119 User Guide HWD 2102 REVISED MARCH 2020 14 Wiring Diagram ...

Reviews: