Fetco E1241IN-1B123-PM000 Users Manual And Operator Instructions Download Page 7

Go to fetco.com for the latest versions of all information         

Page 7

      

User Guide & Operator instructions

   

P212

e0

November 2021

 

B General 

Brewer Operation Control Settings, Adjust Brew Flow Rate

 

POSITION 

Program Items 

Factory set Default 

Programming Range  Increments 

Notes 

B1 

Tank Temp. 

200°F-or-93° C 

NOTE: Equipment is 

Fahrenheit by default 

77° to 97°C 

170°F to 207°F 

0.5°C 

1.0°F 

Chart to correct for high 

altitude below 

B2 

Brew at Temp. 

“YES” 

ON/OFF 

YES/NO 

SEE NOTE BELOW  

B4 

Show Tank 

Temperature 

YES 

YES/NO 

 

To display HW tank 

temperature on screen

 

B5 

Units of Measure 

TEMPERATURE 

° Fahrenheit 

Fahrenheit/Celsius 

C/F 

NOTE

: Overwrites user 

settings 

(see page 9)

 

B6 

Units of Measure 

VOLUME 

Gallons 

Gallons/Liter/Ounces 

L/Gal/Oz 

NOTE

: Overwrites user 

settings 

(see page 9)

 

B7 

Customer Name 

Off 

NO or YES 

 

For name on screen 

B7 

Customer Name 

(only if above is “ON) 

Scroll with batch 

keys 

A-Z;a-z;0-9 

16 characters total 

B9 

Demo Mode 

DEMO ON/OFF 

 

 

Demonstrates the controls for 

training. Disables all 

components in demo mode

 

B10 

Eco Mode 

On 

ON/OFF 

YES/NO 

If Selected: Lowers hot water 

tank temperature after preset 

time of inactivity 

B11 

Eco Idle Time 

1Hr 

1-6 hours 

1 hour 

Time of inactivity to go into 

ECO Mode 

B12 

Eco Idle Temp 

170°F 

158-176°F 

1 degree 

Temperature that hot water 

tank is lowered to when in 

ECO Mode 

B13 

Filter Life 

OFF 

ON/OFF 

YES/NO 

Water filter life is accessed in 

G-Counters. This is user set 

and will display indicator to 

change water filter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chart to correct for altitude for boiling point   

in tank water temperature.

 

[ft] 

[m]  Suggested 

Setting[°F] 

Boiling 

point[°F] 

Suggested 

Setting[°C] 

Boiling 

point [°C] 

205 

212.0 

96 

100.0 

500  152 

205

 

211.0 

96

 

99.5 

1000  305 

200

 

210.1 

93

 

98.9 

2000  610 

200

 

208.1 

93

 

97.8 

2500  762 

200

 

207.2 

93

 

97.3 

3000  914 

200

 

206.2 

93

 

96.8 

3500  1067 

197 

205.3 

92 

96.3 

4000  1219 

195 

204.3 

91 

95.7 

4500  1372 

194 

203.4 

90 

95.2 

5000  1524 

194 

202.4 

90 

94.7 

5500  1676 

193 

201.5 

89 

94.2 

6000  1829 

192 

200.6 

89 

93.6 

6500  1981 

191 

199.6 

88 

93.1 

7000  2134 

190 

198.7 

87 

92.6 

7500  2286 

188 

197.8 

86 

92.1 

8000  2438 

187 

196.9 

86 

91.6 

8500  2591 

185 

196.0 

85 

91.1 

BREW AT TEMPERATURE DEFINITIONS 

DEFAULT: BREW AT TEMP:  “ON” 

 

 

(FACTORY  DEFAULT FOR BREWER) 

 

“BREW at TEMP:   

-Batch will not start if tank temperature 

 is below set point. 

-Display will show “HEATING” 

 and hot water tank temperature 

The “BREW START” entry buttons will not 

illuminate until the hot water tank reaches the 

selected temperature.   

 

Controls allow both sides of dual brewer to 

operate if one side has an ongoing brew 

started and the second side brew is selected.   

 

Notifications shown on screen: 

TEXT: 

HEATING

Tank above 87°C/189°F-will 

allow  brew at low temperature.   

Coffee flavor may be affected 

TEXT: 

L. HEAT

Tank above 76°C/169°F-will 

allow brew at low temperature.   

Coffee flavor will be noticeably affected 

 

 

 

Hot water tank not at 

brew temp setpoint. 

 

Tank temp

 

 

STOP is not lit

 

 

 

BREW START 

buttons not lit. 

and are disabled

 

When hot water tank 

temperature is at 

setpoint.  Buttons will 

illuminate and 

“READY” will be 

displayed 

 

                         

vv

vv

vv 

 

HEATING 

160°F 

  

 

  

 

  

 

    

USER SELECTABLE OPTION: BREW AT TEMP:

  

OFF

    

 

(Not recommended) 

 Unit will operate at cold temperature

 

Allows brewing at any temperature above 77°C/170°F 

Below 70°C/170°F The red colored ready lights switch turn off 

STOP 

STOP

 

Summary of Contents for E1241IN-1B123-PM000

Page 1: ...ractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1242 CBS 1241 1 gallon Extractor Plus Brewers shown with 1 gallon L4D dispenser sold separately CONTACT INFORMATION FETCO FOOD E...

Page 2: ...elay Weights and Capacities Model Height Width Depth Water tank capacity Empty Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1241 Brewer 34 in 880 mm 11 in 300 mm 20 3 8 in 520 mm 4 5 g...

Page 3: ...i on Phase Amp Dr aw Brew Volum e per hour E1241C E 1B130 PM000 230 1 X 3 0 kW L N PE 2 8 EU1 16P 1 12 5 7 7 gal 29 1 L CBS 1241PLUS Single 1 Gallon 3 0 4 0 Liter Coffee Brewers Field configurable Int...

Page 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Page 5: ...3 Service Phone G15 Rt Brews A90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right...

Page 6: ...brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10 5 00 1 00 min The time between prewettin...

Page 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Page 8: ...Activates valve Default is 10 sec Toggle OFF or ON Runs valve to verify flow NOTE Have container under brew basket D4 Rt right Brew Valve Test Press to test Activates valve Default is 10 sec Toggle OF...

Page 9: ...te 1 85 liter minute 64 ounces minute 0 42 0 58 Gallons 1 55 2 20 Liters 53 74 fl ounces 0 01G 0 05L 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 0 37 gallon minute 1 60 liters minute 47 ounces...

Page 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Page 11: ...k did not refill within expected time Water supply flow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 200 Heating flatline Tank is b...

Page 12: ...nt Totalized cycles of valve operation CBS 1241 CBS 1242 G29 A Rt Brew Cycles R G30 A Rt Brew Volume LT Right brew valve flow through volume Gallons Liters Totalized volume through right valve CBS 124...

Page 13: ...toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT Note Only the left side buttons of a two sided brewer are used for programming NOTE User Settings will be er...

Page 14: ...such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish a...

Page 15: ...ible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement 6...

Page 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Page 17: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Page 18: ...sions of all information Page 18 User Guide Operator instructions P212e0November 2021 Parts Diagram CBS 1241 FETCO CBS 1241 Drawing Number 1101 00580 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Page 19: ...1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 1 1046 00003 00 LABEL CSD WARNING 1 5 X 5 0 32 1 1041 00033 00 BLACK EXTRACTOR PLUS LABEL LASER ENGRAVED 33 1 1402 00097 10 WI...

Page 20: ...ions of all information Page 20 User Guide Operator instructions P212e0November 2021 Parts Diagrams CBS 1242 FETCO CBS 1242 Drawing Number 1101 00579 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Page 21: ...2232 42 28 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 29 12 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X LG 30 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 2 1046 00...

Page 22: ...ATED 9 1 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00029 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 9 1 1107 00037 00 HEATER...

Page 23: ...0 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 2 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00029 00 HEATER ASSEMBLY...

Page 24: ...8 12 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00037 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 2 1107 00005 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 9 2 1107 00010 00 HEATER ASSEM...

Page 25: ...1102 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078...

Page 26: ...6 User Guide Operator instructions P212e0November 2021 Wiring Diagrams SSR SSR SKU E1231 US 1X117 Domestic Dual Voltage Brewer is supplied by factory as 120VAC For 208 240 volt application conn ect L1...

Page 27: ...ons of all information Page 27 User Guide Operator instructions P212e0November 2021 S S R Wiring diagram 1401 00190 10 CBS 1241PLUS SKU E1241US 1A115 PM001 E1241US 1A123 PM002 E1241IN 1B123 PM000 E124...

Page 28: ...ions of all information Page 28 User Guide Operator instructions P212e0November 2021 SSR Wiring diagram 1401 00196 10 CBS 1242 PLUS SKU E1242US 1B223 PM000 E1242US 1B230 PM000 E1242IN 1B223 PM000 E124...

Reviews: