Programing Menu Layout

 

 

 

 

 

A10 to A70 

 

B10-B40 

 

C10-C50 

 

D10-D90 

 

E10-E70 

 

F10-F120 

 

G1-G15 

 

H10-H11 

 

 

Batch Parameters 

 

General Settings 

 

Service Inputs 

 

Service Outputs 

 

Calibration 

 

Service Menu 

 

Counters 

 

Exit and Save 

 

 

 

 

 

 

 

 

 

 

A11 

Brew Volume 

B1 

Tank Temperature 

C1 

LLC Probe 

D1 

Heater SSR 

E1 

Ready Temp. Offset 

F1 

Firmware Ver. 

G1 

Filter Used 

H1 

Save Changes 

 

 

 

 

 

 

 

 

 

 

A12 

Brew Time 

B2 

Brew at Temp 

C2 

Basket Sensor 

D2 

Fill Valve 

E2 

LLC Sensitivity 

F2 

Bootloader Ver. 

G2 

Filter Life 

H2 

EXIT? 

 

 

 

 

 

 

 

 

 

 

 

A13 

Prewet Percent 

B5 

Show Tank Temp 

C4 

Tank Temperature 

D3 

Lt Brew Valve 

E3 

Slow Flow Compensate 

F3 

Select Model 

G3 

Filter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A14 

Prewet Delay 

B4 

Units of Temp 

C5 

USB Drive 

D4 

Rt Brew Valve 

E4 

Lt Brew Flow 

F4 

Option Bypass 

G4 

Counter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A16 

Drip Delay 

B6 

Units of Volume 

C6 

Keyboard Test 

D12 

LCD Brightness % 

E5 

Rt Brew Flow 

F5 

Option BB Lock 

G5 

Choose Counter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A20 

Batch (2) Enabled 

B7 

Customer Name 

 

 

D13 

LED Brightness % 

 

 

F8 

Backup to USB 

G10 

Brewer Volume 

[T]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A21 

Brew Volume 

B7 

Customers Name 

 

 

 

 

 

 

F9 

Restore from USB 

G11 

Brewer Volume 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A22 

Brew Time 

B9 

Demo Mode 

 

 

 

 

 

 

F10 

Restore Defaults 

G12 

LT Brews[T] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A23 

Prewet Percent 

B10 

Eco Mode 

 

 

 

 

 

 

F11 

Error Log 

G13 

LT Brews 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A26 

Drip Delay 

B11 

Eco Idle Time 

 

 

 

 

 

 

F12 

Erase Error Log 

G14 

Rt Brews [T] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A30 

Batch (3) Enabled 

B12 

Eco Idle Temp 

 

 

 

 

 

 

F13 

Service Phone# 

G15 

Rt Brews  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A90 

Copy Batch 

B13 

Filter Life 

 

 

 

 

 

 

F14 

Override Lt BBS 

 

See Page 12 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A91 

Copy Batch: From 

 

 

 

 

 

 

 

 

F15 

Override Rt BBS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A92 

PASTE: To 

 

 

 

 

 

 

 

 

F16 

Override Lt BBL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F17 

Override Rt BBL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left and Right top and middle batches are permanent  SEE BOX on the following page for all “A” menus

 

 

The “A” menu is the most accessed menu.  It is for programming the batch volumes, brewing parameters, enabling or 

disabling brew buttons.  The “A” menu moves through the six positions(CBS-1242+) or three positions(CBS-1241+) by 

entering the menu and pressing the left stop button.  (only the left side is active for programming the CBS-1242+) 

 

The A menus [A1-3 or A1-6] correspond to batch buttons [3 or 6] on the touch panel 

Access the A menus to PROGRAM & make changes to individual menu recipes.  Menu settings can be copied  

Menu positions A1 and A4 [top position] are permanent.  Menus A2, A3, A5, A6 can be removed by operator if desired 

 

 

 

 

 

 

From A PRG screen 

Press button 1 to go to 

the A menu access 

screen 

From A11 screen 

Press 

STOP

 to scroll 

to A20.  

(A1&A4 are permanent) 

From A20 screen 

Press STOP to  

scroll through the 

remaining (3 or 6) 

“A” menus.  Make 

any changes as 

required 

From A60 screen 

Scroll out to 

remaining A10-to 

A70 programming 

keys.  See SAVE & 

EXIT in previous 

table 

For single and twin 

Position of batch buttons 

for CBS-1232+  

 

The CBS-1231+ single 

position brewer has  one 

row of buttons  

 

 

 

 

  Batch Program 

  A 

STOP 

STOP 

STOP 

  Brew Volume 

  A1.10   3.80L  +/- 

STOP 

STOP 

  Batch Enabled 

  A6.00            NO+ 

STOP 

  

(Dual model shown)

 

  Batches A1 to A6 

STOP 

STOP 

A1 

A2 

A3 

A4 

A5 

A6 

  Batch Enabled 

  A2.00           YES - 

STOP 

STOP 

Summary of Contents for E1241IN-1B123-PM000

Page 1: ...ractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1242 CBS 1241 1 gallon Extractor Plus Brewers shown with 1 gallon L4D dispenser sold separately CONTACT INFORMATION FETCO FOOD E...

Page 2: ...elay Weights and Capacities Model Height Width Depth Water tank capacity Empty Weight Filled Weight Shipping Weight Shipping Dimensions CBS 1241 Brewer 34 in 880 mm 11 in 300 mm 20 3 8 in 520 mm 4 5 g...

Page 3: ...i on Phase Amp Dr aw Brew Volum e per hour E1241C E 1B130 PM000 230 1 X 3 0 kW L N PE 2 8 EU1 16P 1 12 5 7 7 gal 29 1 L CBS 1241PLUS Single 1 Gallon 3 0 4 0 Liter Coffee Brewers Field configurable Int...

Page 4: ...rew basket 5 Select a batch hold the corresponding BREW button in for 1 second to start 6 STOP button will illuminate Countdown time will display Selected BREW button will flash to indicate brew is in...

Page 5: ...3 Service Phone G15 Rt Brews A90 Copy Batch B13 Filter Life F14 Override Lt BBS See Page 12 A91 Copy Batch From F15 Override Rt BBS A92 PASTE To F16 Override Lt BBL F17 Override Rt BBL Left and Right...

Page 6: ...brew time is 5 30 minutes A2 30 Prewet Perc 0 0 00 25 0 1 Percentage of total brew volume A2 40 Prewet Delay Brew pause after prewet completes 0 1 00 Min 0 10 5 00 1 00 min The time between prewettin...

Page 7: ...mperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 2...

Page 8: ...Activates valve Default is 10 sec Toggle OFF or ON Runs valve to verify flow NOTE Have container under brew basket D4 Rt right Brew Valve Test Press to test Activates valve Default is 10 sec Toggle OF...

Page 9: ...te 1 85 liter minute 64 ounces minute 0 42 0 58 Gallons 1 55 2 20 Liters 53 74 fl ounces 0 01G 0 05L 1 oz Adjusts flow rate E6 LT Bypass valve flow rate 0 37 gallon minute 1 60 liters minute 47 ounces...

Page 10: ...NO Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F10 Restore Defaults NO NO YES Reset to factory When selecting F10 RESTORE...

Page 11: ...k did not refill within expected time Water supply flow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 200 Heating flatline Tank is b...

Page 12: ...nt Totalized cycles of valve operation CBS 1241 CBS 1242 G29 A Rt Brew Cycles R G30 A Rt Brew Volume LT Right brew valve flow through volume Gallons Liters Totalized volume through right valve CBS 124...

Page 13: ...toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT Note Only the left side buttons of a two sided brewer are used for programming NOTE User Settings will be er...

Page 14: ...such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polish a...

Page 15: ...ible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replacement 6...

Page 16: ...nit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or aut...

Page 17: ...BB HANDLE 1023 00191 00 GREEN PLUG BB HANDLE 1023 00192 00 ORANGE PLUG BB HANDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Qty Part Number Description B003218B1 Complete Stain...

Page 18: ...sions of all information Page 18 User Guide Operator instructions P212e0November 2021 Parts Diagram CBS 1241 FETCO CBS 1241 Drawing Number 1101 00580 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Page 19: ...1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 1 1046 00003 00 LABEL CSD WARNING 1 5 X 5 0 32 1 1041 00033 00 BLACK EXTRACTOR PLUS LABEL LASER ENGRAVED 33 1 1402 00097 10 WI...

Page 20: ...ions of all information Page 20 User Guide Operator instructions P212e0November 2021 Parts Diagrams CBS 1242 FETCO CBS 1242 Drawing Number 1101 00579 00 6 Part Number1102 00471 00 ELECTRICAL COMPONENT...

Page 21: ...2232 42 28 1 1001 00409 00 COVER UPPER BASE CBS 2232 42 29 12 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X LG 30 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 2 1046 00...

Page 22: ...ATED 9 1 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 1 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 1 1107 00029 00 HEATER ASSEMBLY IMMERSION 2300W 120VAC 9 1 1107 00037 00 HEATER...

Page 23: ...0 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00030 00 HEATER ASSEMBLY IMMERSION 1500W 120VAC 9 2 1107 00031 00 HEATER ASSEMBLY IMMERSION 1700W 120VAC 9 2 1107 00029 00 HEATER ASSEMBLY...

Page 24: ...8 12 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 9 2 1107 00037 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 9 2 1107 00005 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 9 2 1107 00010 00 HEATER ASSEM...

Page 25: ...1102 00113 00 SWITCH REED ASSEMBLY 5 1 1102 00479 00 ASSEMBLY CASCADE SPRAY DOME NEXT GEN ORANGE 6 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 6 2 1057 00078...

Page 26: ...6 User Guide Operator instructions P212e0November 2021 Wiring Diagrams SSR SSR SKU E1231 US 1X117 Domestic Dual Voltage Brewer is supplied by factory as 120VAC For 208 240 volt application conn ect L1...

Page 27: ...ons of all information Page 27 User Guide Operator instructions P212e0November 2021 S S R Wiring diagram 1401 00190 10 CBS 1241PLUS SKU E1241US 1A115 PM001 E1241US 1A123 PM002 E1241IN 1B123 PM000 E124...

Page 28: ...ions of all information Page 28 User Guide Operator instructions P212e0November 2021 SSR Wiring diagram 1401 00196 10 CBS 1242 PLUS SKU E1242US 1B223 PM000 E1242US 1B230 PM000 E1242IN 1B223 PM000 E124...

Reviews: