CBS-7000
Series Brewers & Dispensers
P186 JANUARY 2020
Programming
Turn the power switch on.
CONTROL BOARD
Display
Hold the
SET
button for 3 seconds, until the display reads SET.
SET
The display will show 0.0 briefly,
0.0
followed by the software version. Example: 10.A
10.A
The display shows the
actual water temperature
when not in Programming
mode.
Press
SET
. The first parameter number will be displayed briefly,
1.0
followed by the current setting.
312
Example: 1.0 = Brew orifice, .312”
Use the
UP
and
DOWN
buttons to adjust the setting.
Press
SET
again. The next parameter will be displayed briefly,
1.1
followed by the current setting.
0
Example: Bypass percent, 0%
Use the
UP
and
DOWN
buttons to adjust the setting.
Continue this way until all parameters are programmed.
See the chart below for an explanation of each parameter.
Important! To save your changes and return to operating mode,
you must hold
SET
for 3 seconds until the display reads STo.
STo
The unit will automatically return to normal operating mode after 30
seconds without programming activity, and changes will not be saved.
Parameter
Name
Range
Increment
Standard Factory
Setting
Comment
0.0
Software Version
Displays current version.
1.0
Brew orifice size
Five available
sizes: .250,
.281, .312,
.343, .375.
.312
This is the size of the hole in
the brew orifice, which
controls how fast water is
dispensed.
1.1
Bypass Percent
0.00 – 35.0%
5%
0 %
Percentage of total brew
volume.
1.2
Drip Delay
(Min:Sec)
1 – 5 minutes
10 sec.
1:30
Time between the end of the
brew cycle and the brew light
stops flashing.
1.3
Auto Transfer Pump 1 – 6 minutes
10 sec.
4:00
Transfer units only.
This is the amount of time the
transfer pump runs after a
brew cycle when the “Auto
Transfer” switch is on.
2.0
Water Temp. (°F)
180°F - 208°F
1°F
205°F
3.0
Brew Wait
ON - OFF
OFF
OFF = Brewer must be at set
temperature (READY light on)
to start a brew cycle.
ON = If the BREW button is
pressed when the unit is not
at the set temperature, the
brewer will wait until it heats
up, and then begin brewing.
The READY and BREW lights
flash during the waiting time.
1
Standard factory settings apply unless custom settings were requested at the time of order.
2
Non-standard size brew orifices must be ordered from FETCO.
Error Codes
050 - Shorted Temp Probe
051 - Open Temp Probe
070 - Stuck switch
(Switch stuck or held in for
more than 45 seconds.)
Error codes are displayed
on the control board.
To reset, turn the power
switch off and on.