3
Electrical Configuration and Brewing Efficiency
US & Canada
CBS-2041
1.0 gallon per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 11)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E41046
1 X 1.5 KW
120
single 2 + ground
1.6
13.0
3.8
9.3
Can be connected
2 X 1.5 KW
120/208
single 3 + ground
2.4
11.3
5.8
11.0
to 120 VAC or
120/220
2.6
12.0
6.5
11.0
120/208-240 VAC
120/240
3.1
13.0
7.7
11.0
E41036
1 X 1.7 KW
120
single 2 + ground
1.8
14.7
4.4
10.5
Can be connected
2 X 1.7 KW
120/208
single 3 + ground
2.7
12.8
6.5
11.0
to 120 VAC or
120/220
3.0
13.5
7.3
11.0
120/208-240 VAC
120/240
3.5
14.7
8.7
11.0
E41016
1 X 2.3 KW
120
single 2 + ground
2.4
19.7
5.9
11.0
Can be connected
2 X 2.3 KW
120/208
single 3 + ground
3.6
17.1
8.9
11.0
to 120 VAC or
120/220
4.1
18.1
9.9
11.0
120/208-240 VAC
120/240
4.7
19.7
11.0
11.0
CBS-2042
1.0 gallon per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 22)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E42016
2 X 3 KW
120/208
single 3 + ground
4.6
22.4
11.5
22.0
120/220
5.1
23.7
12.9
22.0
120/240
6.1 25.8
15.4 22.0
* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.
Export
CBS-2041
1.0 gallon per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 11)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E41026
1 X 3 KW
220
single 2 + ground
2.6
12.0
6.5
11..0
CBS-2042
1.0 gallon per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 22)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E42026
2 X 3 KW
220
single 2 + ground
5.1
23.7
12.9
22.0
* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.