Technical data
RS 100 CQ
Power
520 W
Speed
6300 min
-1
Working strokes
12600 min
-1
Sanding stroke
5.0 mm
Sanding shoe
115 x 221 mm
Weight according to
EPTA-Procedure 01:2014
3 kg
The specifi ed illustrations can be found at the
beginning of the operating instructions.
Symbols
Warning of general danger
Wear a dus
t mask!
Wear protective goggles!
Read the Operating Instructions/Notes!
Wear ear protection!
Do not throw in the household waste!
Protection class II
1 Intended
use
As specifi ed, the machines are designed for sand-
ing wood, plastic, metal, stone, composite mate-
rials, paint/varnish, fi ller and similar materials.
Materials containing asbestos must not be pro-
cessed.
For reasons of electrical safety the machine must
not be damp nor operated in a humid environment.
The machine may only be used for dry sanding.
The user is liable for damage and injury
resulting from incorrect usage!
2 Safety
instructions
2.1 General
Safety
WARNING! Read all safety warnings, in-
structions, illustrations and specifi cations pro-
vided with this power tool.
Failure to follow the
warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future
reference.
The term “power tool” in the warnings refers
to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
2.2 Tool-specifi c safety rules
Always wear protective goggles because
of possible dangers when sanding.
- The manufacturer’s handling and processing
instructions must be observed without fail if
explosive or self-igniting dusts are likely to oc-
cur during sanding.
- Harmful/toxic dusts can occur during your work
(e.g. lead-containing paint, some types of wood
and metal). Contact with these dusts, espe-
cially inhaling them, can represent a hazard for
operating personnel or persons in the vicinity.
Comply with the safety regulations that apply in
your country. Connect the electric power tool to
a suitable extraction system.
To protect your health, wear a P2 protec-
tive mask.
-
Only for AS/NZS:
The tool shall always be sup-
plied via residual current device with a rated
residual current of 30 mA or less.
2.3
Noise and vibration information
The typical values determined in accordance with
EN 62841 (see EU Declaration of Conformity) are:
Sound-pressure level
82 dB(A)
Sound-power level
93 dB(A)
Measuring uncertainty allowance
K = 3 dB
Wear ear protection!
Overall vibration levels (vector sum for three direc-
tions) measured in accordance with EN 62841 (see
EU Declaration of Conformity):
Vibration emission level
(3 directions)
a
h
= 5.6 m/s
2
Uncertainty
K = 1.5 m/s
2
The specifi ed emissions values (vibration, noise)
– are used to compare machines.
– They are also used for making preliminary
estimates regarding vibration and noise loads
during operation.
– They represent the primary applications of the
power tool.