Automatic cleaning
Activate AutoClean or set the frequency using
the rotary knob [1-8] (depending on the mobile
dust extractor variant).
Manual cleaning
Turn the switch [1-11] to the AC symbol.
Full manual cleaning
► Cover the end of the nozzle or suction hose
with your hand or CT-VS closing slide for
two seconds.
► Turn the switch [1-11] to the AC symbol.
8.3
Special features of the CTM 36 E AC-
LHS
To use the mobile dust extractor in combination
with the PLANEX:
► Use kink-resistant suction hose D 36 mm x
3.5 m-AS.
► Use a special suction sleeve for connecting
the PLANEX.
► Use closing slide CT-VS between the intake
opening [1-2] and suction hose.
► Attach the tool holder.
► Always use with a disposal bag!
8.4
Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Use a filter or disposal bag when extracting
hazardous materials!
► Do not use the machine if the volumetric
flow monitoring function is inactive.
Observe the following when extracting dust
generated by operating electric power tools:
If the exhaust air is discharged back into the
room, the air renewal rate L within the room
must be sufficient. The volume of air dis
charged back into the room must not exceed
50% of the fresh air volume flow (room volume
V
R
x air renewal rate L
W
). Observe all the rele
vant regional regulations.
Remember: A moist main filter clogs more
quickly when extracting dry materials. There
fore, dry the main filter before extracting dust
or replace the damp filter with a dry one.
8.5
Extracting wet materials/liquids
Remove the filter/disposal bag.
Use a special wet filter (NF-CT).
The dust extraction stops automatically when
the maximum fill level is reached.
It must be ensured that the machine (main fil
ter, suction hose, container, etc.) is sufficiently
dried after extracting wet materials.
CAUTION
Hazardous dust
Damage to the respiratory passage
► After extracting wet materials, remove the
wet filter and replace it with the main filter
for dry materials.
CAUTION
Escaping foam and liquids
► Switch off and empty the machine immedi
ately.
8.6
After finishing work
► Variants with AutoClean only: Clean the
main filter automatically or manually (see
► Switch off the mobile dust extractor and
pull out the mains plug.
► Wind up the mains power cable.
► Empty the dirt trap.
► Close the extractor connector [1-2] using
the plug [1-1].
WARNING
Hazardous dust
Damage to the respiratory passage
► Before removing the mobile dust extractor
from the contaminated area, clean it and
all accessories by thoroughly vacuuming
and washing them down (interior and exte
rior).
► Parts that cannot be thoroughly cleaned
must be sealed in an airtight plastic bag
during transportation.
► Wear a dust mask.
Only store this machine indoors.
► Place the mobile dust extractor in a dry
room inaccessible to unauthorised users.
English
21