11
CT 17 E
2
Symbols
Symbol Significance
Warning of general danger
Risk of electric shock
Read operating instructions and
safety notices!
Symbol Significance
Disconnect from the power supply!
Wear a dust mask.
Do not dispose of as domestic
waste.
Extracting fluids
3
Technical data
Mobile dust extractors
Power consumption
Max. appliance socket
connected load
EU (230 V, 50 Hz)
400 – 1200 W
CH, DK (230 V, 50 Hz)
1100 W
GB (240 V, 50 Hz)
1800 W
AUS (240 V, 50 Hz)
1200 W
Max. suction capacity (air),
extractor/turbine
3000 l/h / 3700 l/min
Max. vacuum, turbine
24000 Pa
Filter surface area
4600 cm
2
Suction hose
D 27 mm x 3.5 m
Length of the net cable
5.5 m
Sound pressure level as per
EN 60704-2-1 / Uncertainty K
74 dB(A) / 3 dB
Protection category
IP X4
Safety class
I
Container capacity
17 l
Dimensions L x W x H
445 x 380 x 485 mm
Weight
9.4 kg
4
Machine features
[1-1]
Intake opening
[1-2]
Switch
[1-3]
Suction power adjuster
[1-4]
Appliance socket
[1-5]
Folding handle
[1-6]
Locking clip
[1-7]
Dust container
[1-8]
Cable/hose holder
[1-9]
Exhaust opening
The specified illustrations appear at the beginning
of the Operating Instructions.
5
Intended use
Mobile dust extractor suitable for
– Extracting non-hazardous dust, dirt, sand and
chips,
– Extracting water,
– Increased loads during commercial use,
according to IEC/EN 60335-2-69.
The user is liable for improper or non-
intended use.