CTH
17
GB
We also recommend installing the VE service unit
(495886). The service unit filters and lubricates the
compressed air and enables an adjustment of the
air pressure. An IAS adapter (454757) is available to
connect Festool pneumatic tools to the IAS system.
The operating pressure of the tool must be 6 bar for
the automatic switch-on unit to function correctly.
7.4
Adjusting the suction power
Use the rotary knob
[1-9]
.
7.5
Applying the brake
Folding out the black brake lever
[1-15]
prevents
the mobile dust extractor from rolling. To achieve
this, lift the front end of the mobile dust extractor
slightly and push the black brake lever downwards
until it latches into place. Push the green lever
[1-
14]
again to release.
7.6
Temperature cut-out
A temperature cut-out switches the mobile dust ex-
tractor off when it reaches a critical temperature to
prevent overheating.
Switch off the mobile dust extractor, allow to
cool for about 5 minutes then switch on again.
Not possible to switch on: contact Festool ser-
vice workshop.
7.7
Changing the filter bag
(SC-FIS-CT26/48)
Removing the filter bag [4]
Open the locking clips
[2-2]
and remove the top
section of the machine
[2-1]
.
Remove the filter bag.
Dispose of the used filter bag in accordance with
statutory regulations.
Clean the dust container
[2-3]
.
Inserting the filter bag [5]
Insert a new filter bag(SC-FIS-CT26/48) in the
inlet port of the dust container and interlock it.
Important:
be aware that the locking engages.
Make sure that the filter bag is not pinched be-
tween the top and bottom sections.
Replace the top section
[2-1]
and close the
locking clips
[2-2]
.
7.8
Changing the safety filter bag
(FIS-CTH
26/48)
Always use the safety filter bag for absorb-
ing Class H dust.
Removing the safety filter bag [6]
Close off the extractor opening
[1-2]
using the
sealing plug
[1-1]
.
Open the locking clips
[2-2]
and remove the top
section of the machine
[2-1]
.
Knock the material of the plastic bag upwards
and close the lateral openings with the adhesive
tabs.
Close the plastic bag around the filter bag using
the cable ties supplied.
Remove the safety filter bag
Dispose of the used safety filter bag in accor-
dance with statutory regulations.
Clean the dust container
[2-3]
.
Inserting the safety filter bag [7]
Insert a new safety filter bag (FIS-CTH 26/48) on
the inlet nozzle of the container and lock in po-
sition.
Important:
Ensure the lock is snapped in.
Place the plastic bag over the edge of the con-
tainer. The lateral openings on the safety filter
bag must be positioned inside the dirt trap.
Ensure the contacts are
[10-2]
free.
Make sure that the filter bag is not pinched be-
tween the top and bottom sections.
Replace the top section
[2-1]
and close the
locking clips
[2-2]
.
7.9
Volumetric flow monitoring
An acoustic warning signal sounds if the air speed in the suction hose falls below 20 m/s.
Possible causes
Solution
Value set on the suction power adjuster
[1-9]
is
too low.
Set the suction power adjuster to a higher value (see
Chapter 7.4).
Rotary knob
[1-8]
not set to the correct hose
diameter.
Set the knob to the correct hose diameter (see Chapter
7.1).
Suction hose blocked or kinked.
Remove blockage or kink.
Filter bag full.
Insert a new filter bag (see Chapter 7.7).
Dirty main filter.
Changing the main filter (see Chapter 9.1).
Monitoring electronics malfunction.
Send to a Festool service workshop for repair.
Wet extraction.
Functional reliability not affected, no actions required.