background image

Assembly instructions (en) 
745 509 / 2009-03a 

†‡

Control valve 
VSNZ-FT-T32C-M…-F-P1-T... 

Festo SE

 & Co. KG

Postfach 
D-73726 Esslingen 
++49/(0)711/347-0
www.festo.com 

1. Parts list 

12087d_1 

VSNZ-FT-T32C-MH-F-P1-T…

 

1

  Control valve (1x) 

2

  Socket head screw (4x) 

3

  O-ring 15x2 (2x)  

6

  O-ring 3.2x1.8 (4x) 

12087d_2 

 

VSNZ-FT-T32C-M-F-P1-T…

 

1

  Control valve (1x) 

2

  Socket head screw (4x)  

3

  O-ring 15x2 (2x) 

6

  O-ring 3.2x1.8 (4x) 

12087d_3 

4

  Pilot  valve (2x)

1)

 

with Cnomo interface 

5

  Socket head screw (4x) 

2. Prefitting pilot  valve 

12087d_4 

Press the o-rings 

6

 into the 

recesses in the control valve 

1

 intended for this purpose.

12087d_5 

 

Place both pilot valves 

4

 on

control valve 

1

Tighten the screws 

5

. Note 

the permitted tightening 
torque. 

1)

Permitted pilot valves from Festo for control valve VSNZ-FT-T32C… on request. 

3. Assembly 

12087d_6 

Press the o-rings 

3

 into the 

recesses in the control valve 

1

 intended for this purpose.

For fastening to the drive 

12087d_8 

Place the control valve 

1

 on

the drive with NAMUR con-
nections as per 
VDI/VDE 3845

2)

Tighten the screws 

2

. Note 

the permitted tightening 
torque. 

For fitting onto a wall 

12087d_9 

Make sure that the seal 
surface is free of grooves. 

Place the control valve 

1

 on

the wall. 

Tighten the screws 

2

. Note 

the permitted tightening 
torque. 

12087d_10 

Unscrew and remove the 
sealing screws (A) and 
sealing rings (B) from work 
connections 2 and 4. 

Pneumatic connections of the control valve 

Remove the protective foil before inserting the screws. 

1/3

82/84

4/2

G

1

/

4

G

1

/

G

1

/

4

 (G

1

/

8

 for fitting onto a wall) 

4. Circuit diagrams 

VSNZ-…-…-MH-…

VSNZ-…-…-M-…

992042 

992120 

5. During setting/power failure on control valve VSNZ-…-…-MH-…: 

Note 

Commissioning the manual override:  

Remove both spring plugs (C). 

When work is finished: 

Deactivate the manual override by inserting the two spring plugs (C) in
the hole again. 

12087d_11 

2

 

)

Due to the weight of the control valve all four screws are required here. A coding pin as in 
the NAMUR standard is not intended here. 

2.9 Nm +20%

2.9 Nm +20%

1.4 Nm +20% 