![Festo VPPM Operating Instructions Download Page 4](http://html1.mh-extra.com/html/festo/vppm/vppm_operating-instructions_2283288004.webp)
10
Malfunctions
Status of the LED displays
Cause
Green LED [power]
Red LED [error]
–
Undervoltage or overvoltage
of the setpoint value
on
on
–
Hardware error
–
Overvoltage (
>
30 V)
–
Internal temperature too
high
on
flashes
–
Undervoltage (
<
18 V)
off
off
Tab. 9: Status of the LED displays
Fault clearance
Malfunction
Possible cause
Remedy
Device does not respond
No supply voltage, LED [power]
off.
Check the connection of the
supply voltage 24 V DC.
No data communication.
–
Check control unit.
–
Check connection.
Flow rate too low
Restriction of the flow cross
section by connection tech-
nology.
Use alternative connections.
Pressure rise too slow
Large cylinder volume and long
tube length.
Select another parameter set.
Pressure constant despite
modified setpoint specification
Break in the electrical con-
necting cable.
Replace supply cable.
Supply pressure P1 too low.
Increase supply pressure.
Manual selection of parameter
sets with the [UP] and [DOWN]
keys on the device is not pos-
sible
Voltage is applied at digital
inputs D1 and D2.
Apply 0 V DC at digital inputs
D1 and D2.
Tab. 10: Fault clearance
11
Technical data
General technical data
Design
Proportional-pressure regulator
Mounting position
As desired, preferably horizontal (display elements
facing upwards)
Materials
Housing
Wrought aluminium alloy
Cover
PAXMD6 GF50/gr-P
Seals
Nitrile rubber
Lubrication
silicone-free
Weight
VPPM-6...
[g]
400
VPPM-8...
[g]
560
VPPM-12...
[g]
2050
Tab. 11: General technical data
Operating and environmental conditions
Medium
Compressed air in accordance with ISO 8573-1:2010
[7:4:4] inert gases
Information on operating
medium
Lubricated operation not possible
Degree of protection
IP 65 when mounted, with tightened mounting screws,
in combination with plug socket according to accesso-
ries.
Ambient temperature
[°C]
0 … 60
Temperature of medium
[°C]
10 … 50
Storage temperature
[°C]
–10 … +70
Vibration and shock
Vibration
Tested in accordance with DIN/IEC
68/EN 60068 Part 2-6; wall mounting: 0.35 mm path
at 10 … 60 Hz, 5 g acceleration at 60 … 150 Hz
1)
Shock
Tested in accordance with DIN/IEC
68/EN 60068 Part 2-27; wall mounting: ±30 g at 11 ms
duration; 5 shocks per direction
1)
1) Information does not apply when mounting the VPPM-.../VPPX-... on bracket VAME-P1-A/-T.
Tab. 12: Operating and environmental conditions
VPPM-...
0L2H
0L6H
0L10H
Pressure ranges
Permissible input pressure P1
[MPa]
0 … 0.4
0 … 0.8
0 … 1.1
[bar]
0 … 4
0 … 8
0 … 11
[psi]
0 … 58
0 … 116
0 … 159.5
Control range (output pressure
P2)
1)
[MPa]
0.002 … 0.2
0.006 … 0.6
0.01 … 1
[bar]
0.02 … 2
0.06 … 6
0.1 … 10
[psi]
2.9 … 29
8.7 … 87
1.45 … 145
Total leakage when new
[l/h]
<
5
Connection
G 1/8, 1/8 NPT, G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
VPPM-...
0L2H
0L6H
0L10H
Nominal width
Pressurisation
[mm]
6 for VPPM-6...
8 for VPPM-8...
12 for VPPM-12...
Exhaust port
[mm]
4.5 for VPPM-6...
6 for VPPM-8...
12 for VPPM-12...
1) Input pressure P1 at least 0.1 MPa (1 bar, 14.5 psi) above output pressure P2.
Tab. 13: Characteristic pneumatic values
Characteristic electrical values
Electrical connection
Pin contact M12x1, 8-pin
Permissible operating voltage
[V DC]
21.6 … 26.4
Permissible residual ripple max. 10%
Power rating of digital switching
output D3 (PIN 8 in el. connection)
[mA]
max. 60
Max. permissible supply line
length and signal line length
[m]
10
Max. electrical power consumption
VPPM-6... and VPPM-8...
[W]
7
VPPM-12L-...
[W]
12
Voltage type VPPM-...-V1...
Setpoint variable
[V DC]
0 … 10
Input resistance (setpoint value)
[kΩ]
10
Output actual value load
[kΩ]
min. 2
Current type VPPM-...-A4...
Setpoint variable
[mA]
4 … 20
Input resistance (setpoint value)
[Ω]
250
Output actual value load
[Ω]
max. 500
Tab. 14: Characteristic electrical values
Control characteristics
1)
Linearity
1% Full Scale (FS)/2% Full Scale (FS)
Hysteresis
0.5% Full Scale (FS)
Reproducibility
0.5% Full Scale (FS)
Total accuracy
1.25% (S1)/2.25 (2%)
Temperature coefficient
0.04/K
1) Maximum deviation, characteristic values determined at room temperature in accordance with ISO 10094.
Linearity refers to the ideal characteristic curve.
Tab. 15: Control characteristics