6.3 Symbols on the display of the VPPM−...C1
Menu level
Symbol
Description
Out
/
Switching output set/not set
[Out]
Switching output
[SP]
Threshold value comparator
Switching point
[SP max]
[SP min]
Window comparator
Upper switching point
Lower switching point
SP.O.
S
et
P
oint
O
K
[HY]
Hysteresis
[NO]
[NC]
Contact (normally open)
Contact (normally closed)
In
[In]
Input
[min]
[max]
Lower pressure value
Upper pressure value
[mA] or [V]
1)
,
[%],
[bar], [psi], [kPa]
2)
Units of the input
Force
[Force]
Manual setpoint specification
Set...
[Set 1], [Set 2], [Set 3]
Factory parameter sets
SPEC
[SPEC]
Special menu
[LOCK]
Security code active (blocked against unautho
rised programming)
[kPa], [psi], [bar]
Units of pressure, can be switched
Pressure display as bar chart
1)
Depends on the variant of the VPPM−...C1
2)
Depends on unit set in SPEC menu
Fig.18
6.4 Symbols for representing the menu structure
Symbol
Meaning
80s
(Timeout)
Automatic return to the basic status (RUN mode) when the monitoring time
has expired (e.g. here after 80 seconds)
3s
EDIT (Cancel)
In order to return manually to the basic status (RUN mode), press the EDIT
button for 3seconds.
Out
The icon on the display flashes (here Out)
Security code active (lock − blocked against unauthorised programming)
Security code inactive (Lock)
Press button (here UP button)
Press the UP button or the DOWN button to set values or functions)
Press the UP button or the DOWN button to change the functions in the
menu.
Edit
Press the EDIT button.
Fig.19
RUN mode
The RUN mode indicates the current pressure value for the output (Out). By briefly
pressing the DOWN button you can display the setpoint value for the input (In).
SHOW mode (see Fig.20)
If the VPPM−...−C1 is in RUN mode, the SHOW mode will become active when the
UP button or the DOWN button is pressed twice.
If the output (Out) is selected, the current settings of the switching output (Out)
will be displayed one after the other each time the UP button is pressed.
If the input (In) is selected, the minimum pressure value and the maximum pres
sure of the input [In] will be displayed one after the other when the DOWN button
is pressed.
The SHOW mode shows the following settings and values:
Settings for [Out]:
Switching function [threshold value/window comparator/SP.O.]
Switching point [SP] or [SP min] and [SP max]
Hysteresis [HY]
Switching characteristic [NO/NC]
· Press the UP button again several times and check the current values and set
tings of [Out]. After the switching characteristic is displayed you can return to
the RUN mode by pressing the UP button again.
Settings for [In]:
Minimum pressure value [min]
Maximum pressure value [max]
· Press the DOWN button several times and check the current values of [In]. When
the maximum pressure is displayed you can return to the RUN mode by pressing
the DOWN button again.
10s
1) Depending on the setting in the [Out] menu in the EDIT mode
1
)
Fig.20
EDIT mode (see also Fig.21)
The EDIT mode enables the following settings:
In the OUT menu:
Selecting the switching function (threshold value, window comparator or SP.O.)
Setting the switching points [SP] or [SP min] and [SP max]
and hysteresis [HY]
Selecting the switch type [NO/NC] (normally open/closed)
In the IN menu
Setting the minimum and maximum pressure for the pressure regulation range
Selecting the pressure unit [kPa, psi, bar] or [mA/V] or [%] (depending on setting
in menu [SPEC])
In the Set menu:
Selecting a factory parameter set [Set1], [Set2] or [Set3]
In the SPEC menu:
Setting the security code [Lock] and the pressure unit [kPa, psi, bar]