background image

Poportional  pressure  regulator
VPPM−...C1  (LCD)

Festo  AG  &  Co.  KG

Postfach
D−73726  Esslingen
++49/711/347−0
www.festo.com

Operating  instructions

753  264
1007c

Original:  de

Note

Installation  and  commissioning  may  only  be  performed  in  accordance  with  these
operating  instructions  by  technicians  with  appropriate  qualifications.

Note

The  product  is  suitable  for  use  only  for  industrial  purposes.
In  residential  areas,  measures  for  radio  interference  suppression  may  be  necess
ary.

1

Product  description

1.1 Connections,  mounting  holes  and  control  sections  (in−line  valve)

1

4

5

4

2

3

6

1

Electrical  connecting  plug  M12
(8−pin)

2

Air  connection  (2),  pressure  output

3

Exhaust  connection  (3)

4

Through−holes  for  fastening

5

Compressed  air  connection  (1),
supply  port

6

Rating  plate

Fig.1

1.2 Pneumatic  connections  (flanged  valve)

1

2

3

1

Duct  (2)  air,  pressure  output

2

Duct  (1)  compressed  air,  supply  port

3

Duct  (3)  exhaust

Fig.2

1.3 Display  and  control  elements,  display  symbols

1

2

3

4

1

Display

2

DOWN  button

3

EDIT  button

4

UP  button

Fig.3

2

Application  and  function

The  VPPM−...C1  has  been  designed  for  regulating  a  pressure  proportional  to  a
specified  setpoint  value.  A  built−in  pressure  sensor  records  the  pressure  at  the
working  line  and  compares  this  value  with  the  setpoint  value.  If  the  actual  value
differs  from  the  setpoint  value,  the  regulating  valve  is  actuated  further  until  the
output  pressure  reaches  the  setpoint  value.

+W

−W

3

1

2

X

Supply  port

Setpoint  value

Setpoint  value

Pressure  output

Exhaust

Pin  6

Fig.4

3

Variants  of  the  VPPM−...

Type  code  of  the  VPPM−...

1

2

3

5

6

4

7

VPPM − 6L − L − 1 − G18 − 0L6H −

V1N

S1C1

Item

Properties

Meaning

1

Nominal  size  [mm]
Valve  type

6,  8
F  (flanged),  L  (in−line)

2

Dynamic  response  class

L  (Low)

3

Valve  function

1  (3−way  pressure  regulator 

normally  closed)

4

Pneumatic  port
 Flange/sub−base
 ISO  thread
 NPT  thread

F
G18  (1/8"),  G14  (1/4")
N18  (NPT  1/8),  N14  (NPT  1/4)

5

Standard  control  range:
 Lower  pressure  value
 Upper  pressure  value
Alternative  control  ranges: 

1)

 Lower  pressure  value

 Upper  pressure  value

0L  (0  bar)
2H  (2  bar),  6H  (6  bar),  10H  (10  bar)

...L(...  =  value  between  0.1...10  bar)
e.g.  4L
...H  (...  =  value  between 
0.1...10  bar)  e.g.  9H

6

 Setpoint  specification
 Switching  output

A4  (4  ...  20  mA),  V1  (0  ...  10  V)
P  (PNP),  N  (NPN)

7

Accuracy
Operator  unit

...  (2  %,  standard),  S1  (1  %)
...  (LED),  C1  (LCD)

1)

When  an  upper  and  lower  pressure  value  are  used,  it  is  not  possible  to  guarantee  the  overall
accuracy  of  the  VPPM−...C1.

Fig.5

Summary of Contents for VPPM-**C1 Series

Page 1: ...egulating a pressure proportional to a specified setpoint value A built in pressure sensor records the pressure at the working line and compares this value with the setpoint value If the actual value differs from the setpoint value the regulating valve is actuated further until the output pressure reaches the setpoint value W W 3 1 2 X Supply port Setpoint value Setpoint value Pressure output Exha...

Page 2: ...s Fig 8 Wall mounting in line valve Fasten the VPPM C1 in the intended position with two M4 screws In order to do this use angle bracket type VAME P1 A see diagram When mounting the VPPM with the aid of the bracket the VPPM C1 may only be loaded statically torque 1 0 Nm Fig 9 H rail mounting in line valve Mount the H rail adaptor on the VPPM C1 using the screws included x M4 x 65 M4 x 77 tightenin...

Page 3: ...t a switching point manually as follows 1 In order to activate the EDIT mode press the EDIT button Out flashes 2 Press the EDIT button twice SP flashes 3 Edit the threshold value shown with the UP or DOWN button 4 Hold the EDIT button pressed down for 3 s The VPPM C1 will then be in the RUN mode 6 2 Preparing for commissioning Note Make sure that the VPPM C1 is not subjected to high frequency irra...

Page 4: ...Fig 20 If the VPPM C1 is in RUN mode the SHOW mode will become active when the UP button or the DOWN button is pressed twice If the output Out is selected the current settings of the switching output Out will be displayed one after the other each time the UP button is pressed If the input In is selected the minimum pressure value and the maximum pres sure of the input In will be displayed one afte...

Page 5: ...1 Depends on the version of the VPPM C1 2 Depends on the setting in the SPEC menu 1 2 Not in function FORCE Fig 21 EDIT mode ...

Page 6: ...min SP max Fig 24 Switching points SP and hysteresis Hy with NC setting normally closed contact With threshold value comparator setting P 1 0 SP Hy OUT Withwindow comparator setting P 1 0 OUT SP min SP max Hy Hy Fig 25 Configuring the switching output 1 In order to activate the EDIT mode press the EDIT button Only with active security locking Lock flashes 2 Press the UP DOWN button until the desir...

Page 7: ... 1 2 bar type 0 02 bar 2 bar 6 bar type 0 06 bar 6 bar 10 bar type 0 1 bar 10 bar 1 FS Full scale 1 FS 0 1 V or 4 16 mA 100 FS 10 V or 20 mA Output pressure 0 V or 4 mA creates an output pressure of 0 bar Fig 30 Select a suitable parameter set Recommended parameter sets VPPM Sizes 1 8 Tube length 1 Open sys Output values in ml g p y tem 0 100 100 1000 1000 0 m 3 3 2 1 1 m 3 3 2 2 3 m 3 3 3 2 5 m 3...

Page 8: ...socket according to Accessories Perm temp range Ambient Medium Storage C 0 50 10 50 10 70 Vibration and shock Vibration Shock The following data does not apply to mounting the VPPM to the angle bracket VAME P1 A Tested according to DIN IEC 68 EN 60068 part 2 6 for wall mounting 0 35 mm path at 10 60 Hz 5 g acceleration at 60 150 Hz Tested according to DIN IEC 68 EN 60068 part 2 27 for wall mountin...