1.

 

Parts list 

 
 
 

 

 
 

20276d_1 

 VABM-B10-20EEE-... 

1

 Connection 

block 

2

 Screw 

M3

1)2)

 

3

 Screw 

M5 

4

 Seal

1)2)

 

5

 Seal

1)

 

6

 O-ring 

17x2 

7

 O-ring 

10x2 

(1x)
(nx)
(2x)
(nx)
(nx)
(3x)
(2x)

 
 

 

 
 

20276d_2 

 VABM-B10-20EEE-...-P3 

1

 Connection 

block 

2

 Screw 

M3

1)2)

 

3

 Screw 

M5 

4

 Seal

1)

 

5

 Seal

1)

 

6

 O-ring 

17x2 

7

 O-ring 

10x2 

(1x)
(nx)
(3x)
(nx)
(nx)
(2x)
(1x)

20260d_3 

 

Not included in delivery: 

8

 Solenoid 

valve

1)

 

 

                                                                            

1)

 The number of screws 

2

, seals 

4

/

5

 and solenoid valves 

8

 is dependent on the 

available valve positions. 

2)

 Number = 2 x available valve positions 

2.

 

Intended use 

Connection block VABM-B10-...EEE: 
Pneumatic linking of the valves. 

 

3.

 

Safety instructions and notes on assembly 

 

Caution 

Unexpected movement of components. 
Injury due to electric shock, impact, squeezing. 

 

Switch off compressed air before assembly work. 

 

Note 

Malfunction and material damage due to incorrect assembly. 

 

Mount properly (

 section 4 … 6). 

 

Observe tightening torques. 

 

4.

 

Mounting of O-rings 

6

/

7

 

 

20276d_3 

 

 

Place O-rings 

6

/

7

 into the 

depressions. 

 

5.

 

Assembly of connection block 

1

 

 

20276d_4 

 

 

Place connection block 

1

 

on the mounting surface (A).

 

Push connection block 

1

 

onto the connection 
block (B). 
Check: O-rings 

6

/

7

 are 

seated in the depressions. 

 

Tighten screws 

3

 

6.

 

Assembly of solenoid valve 

8

 

 

 

 

20272d_8 

 

 

Place the seal 

5

 in the de-

pression of the solenoid 
valve 

8

 so it is positive-

locking. 

 

Information 

Seals 

4

 can only be mounted with external pilot air supply. 

 

20276d_5 

 

 

Push seals 

4

 into the 

orifices (C). 
Rotating movement 
required during mounting. 

 

Position solenoid valve 

8

 

on the connection block 

1

Check: 

 

Projection (D) is in the 
slot (E) 

 

Solenoid valve 

8

 is aligned 

parallel to the surface (F) 

 

Channel designations 1/3/5 
agree. 

 

Tighten screws 

2

 

1.4 Nm 

_

 20 % 

6  7 

6  7 

4.3 Nm 

_

 20 % 

D