Assembly instructions (Original: de)
8031241
1404NH
†‡
Connection block
VABM-B10-...EEE
Festo AG & Co. KG
Postfach
73726 Esslingen
Germany
+49 711 347-0
www.festo.com
1.
Parts list
20276d_1
VABM-B10-20EEE-...
1
Connection
block
2
Screw
M3
1)2)
3
Screw
M5
4
Seal
1)2)
5
Seal
1)
6
O-ring
17x2
7
O-ring
10x2
(1x)
(nx)
(2x)
(nx)
(nx)
(3x)
(2x)
20276d_2
VABM-B10-20EEE-...-P3
1
Connection
block
2
Screw
M3
1)2)
3
Screw
M5
4
Seal
1)
5
Seal
1)
6
O-ring
17x2
7
O-ring
10x2
(1x)
(nx)
(3x)
(nx)
(nx)
(2x)
(1x)
20260d_3
Not included in delivery:
8
Solenoid
valve
1)
1)
The number of screws
2
, seals
4
/
5
and solenoid valves
8
is dependent on the
available valve positions.
2)
Number = 2 x available valve positions
2.
Intended use
Connection block VABM-B10-...EEE:
Pneumatic linking of the valves.
3.
Safety instructions and notes on assembly
Caution
Unexpected movement of components.
Injury due to electric shock, impact, squeezing.
Switch off compressed air before assembly work.
Note
Malfunction and material damage due to incorrect assembly.
Mount properly (
section 4 … 6).
Observe tightening torques.
4.
Mounting of O-rings
6
/
7
20276d_3
Place O-rings
6
/
7
into the
depressions.
5.
Assembly of connection block
1
20276d_4
Place connection block
1
on the mounting surface (A).
Push connection block
1
onto the connection
block (B).
Check: O-rings
6
/
7
are
seated in the depressions.
Tighten screws
3
.
6.
Assembly of solenoid valve
8
20272d_8
Place the seal
5
in the de-
pression of the solenoid
valve
8
so it is positive-
locking.
Information
Seals
4
can only be mounted with external pilot air supply.
20276d_5
Push seals
4
into the
orifices (C).
Rotating movement
required during mounting.
Position solenoid valve
8
on the connection block
1
.
Check:
–
Projection (D) is in the
slot (E)
–
Solenoid valve
8
is aligned
parallel to the surface (F)
–
Channel designations 1/3/5
agree.
Tighten screws
2
.
8
1.4 Nm
_
20 %
2
3
1
6 7
2
3
5
1
6 7
2
3
A
B
8
5
4
C
E
4
4
5
1
7
6
1
4.3 Nm
_
20 %
8
5
D
1
F