LED display
LED
Meaning
Status LED
(yellow)
Off: normal operation
Flashes/illuminates: warning/error
Error LED
(red)
Off: normal operation
Illuminated: error
Tab. 3 Display of the operating status
In case of warnings or errors, additional CBUS diagnostic messages are sent
è
4
Function
4.1
Function overview
The VABF is a vacuum generator with digital setpoint and actual value transmission via fieldbus. The
VABF can be parameterised via the fieldbus and send diagnostic feedback messages.
The vacuum generator is supplied with compressed air via the valve terminal.
Functions
–
Configuration individual or using parameter sets
è
–
Mechanical manual override
è
–
Monitoring of vacuum build-up through integrated pressure sensor
è
–
Air saving function
è
–
Diagnostic function
è
4.9 Monitoring and diagnostics
–
Teach function for configuration of switching points and monitoring
è
–
VABF-...-AP only: power ejector pulse, to reduce the air flow via the vacuum generator cartridge
and silencer
è
4.7 Power ejector pulse (VABF-...-AP)
4.2
Operating modes
The Operating mode parameter can be used to set the mode of operation of the vacuum generator
VABF.
4.2.1
Data record mode
In the data record mode the parameter sets for the vacuum functions are run and saved via the FMT.
Four different parameters sets can be selected via the process data.
4.2.2
PLC mode
In the PLC mode the parameters for the vacuum functions can be set individually via the process data.
The modified data are not imported until the vacuum generator is in normal position (vacuum genera-
tion and ejector pulse deactivated).
4.3
Switching functions
The binary outputs A and B can be configured via the switching functions. The switching status inform-
ation is made available as a process value.
Function
9