VABF-S4-1-V2B1...
20
Festo – VABF-S4-1-V2B1... – 1705c English
Symbols
Description
Marked segments illuminate:
–
SHOW mode active
–
Diagnostics: 7-segments display shows error number (e.g. Er01)
Marked segments illuminate and [Option] flashes:
–
EDIT mode active
–
Special menu (SPEC) is open; 7-segments display shows the set filter option
Marked segments illuminate and [Lock] flashes:
–
EDIT mode active
–
Special menu (SPEC) is open; 7-segments display shows the security code
Tab. 5
Special symbols of the segment bars
6.2
SHOW mode
The following settings and values are indicated in the SHOW mode:
Settings for Out A/B
–
switching function [threshold/window comparator]
–
switching points [SP] or [SP] [min] and [SP] [max]
–
hysteresis [HY]
–
switching characteristic [NO/NC]
Extreme values of input values
–
minimum pressure value [min]
In order to delete the minimum value, press the EDIT button briefly.
–
maximum pressure value [max]
In order to delete the maximum value, press the EDIT button briefly.
6.2.1
Display settings for Out A/B
The vacuum block must be in the RUN mode.
Press the A-key (switching output Out A) or the B-key (switching output Out B).
è
The SHOW mode of the corresponding switching output is active.
Press the key of the selected switching output again.
è
If you continue pressing the button, the current settings of that switching output will be dis
played one after the other as the button is pressed.
If all values have been displayed and the button is pressed again, the RUN mode is reactivated.
The “Show mode” menu structure can be found in chapter 13.