6
Festo — VABA-S6-1-AP — 2022-06
Installation, electrical
6
Installation, electrical
WARNING
Risk of injury due to electric shock.
• For the electrical power supply, use only PELV circuits in accordance with IEC 60204-1/EN 60204-1
(Protective Extra-Low Voltage, PELV).
• Observe the general requirements of IEC 60204-1/EN 60204-1 for PELV circuits.
• Only use voltage sources that ensure a reliable electric separation from the mains network in
accordance with IEC 60204-1/EN 60204-1.
•
Carry out electrical installation
1 Applicable documents, Operating instructions automation
system CPX-AP-I.
6.1
Interfaces
Connection for power supply [XD1]
M8 plug, 4-pin, A-coded
Signal
1
+24 V DC logic supply PS
2
0 V DC load supply PL
3
0 V DC logic supply PS
4
+24 V DC load supply PL
Tab. 2: Connection for power supply
Observe the information on the power supply, see the operating instructions for the automation
system CPX-AP-I
Connection for voltage forwarding [XD2]
M8 socket, 4-pin, A-coded
Signal
1
+24 V DC logic supply PS
2
0 V DC load supply PL
3
0 V DC logic supply PS
4
+24 V DC load supply PL
Tab. 3: Connection for voltage forwarding