![Festo VABA-S6-1-AP Operating Instructions Manual Download Page 5](http://html.mh-extra.com/html/festo/vaba-s6-1-ap/vaba-s6-1-ap_operating-instructions-manual_2284212005.webp)
Festo — VABA-S6-1-AP — 2022-06
Mounting
5
4
Product overview
4.1
Product design
1
2
3
4
5
6
7
Fig. 1: Product design
1
System communication [XF10]
2
System communication forwarding [XF20]
3
Power supply [XD1]
4
Forwarding supply [XD2]
5
LED module diagnostics [MD]
6
LED load voltage [PL]
7
Earth terminal
4.2
Function
The electrical interface VABA-S6-1-AP provides a connection between a valve terminal VTSA-MP(-NPT)
or VTSA-F-MP(-NPT) and the automation system CPX-AP-I.
5
Mounting
Depending on the configuration, the electrical interface VABA-S6-1-AP is already integrated in the
valve terminal. The product is also suitable for retrofit in existing valve terminals with multi-pin
connection type VTSA-MP (-NPT) and VTSA-F-MP (-NPT).
The product can be fitted with the inscription label ASLR-C-E4.
When retrofitting the VABA-S6-1-AP in existing valve terminals, note the following:
• The installation changes the function of the valve terminal. Before installing the new configuration,
check its validity online with the configurator
• Installing the VABA-S6-1-AP invalidates the current ATEX approval of the valve terminal.
Proceed as follows to install the product:
1. Remove the multi-pin node of the valve terminal
1 Applicable documents, Manual valve ter-
minal VTSA, VTSA-F.
2. Install the electrical interface VABA-S6-1-AP
1 Applicable documents, Manual valve terminal
VTSA, VTSA-F.