Festo SRAP-M-CA1 Series Operating Instructions Download Page 3

Before  mounting

1. Put  the  valve  in  one  of  its  end  positions.
2. Ensure  there  is  no  tension  or  pressure  applied.

Mounting

1. Undo  the  four  socket  head  screws  on  the  cover  (

è

  Fig.1 

2

  ).

2. Carefully  lift  up  the  cover.
3. Using  a  suitable  tool  (e.g.  a  pin  or  screwdriver),  carefully  press  down  the  two  red

release  levers  on  the  pin  strip,  one  after  the  other.  This  releases  the  terminal
strip.

1

Release  levers  on  the
pin  strip

2

Screwdriver

Fig.8

1

2

1

4. Remove  the  terminal  strip  from  the  housing.  You  can  now  access  the  two  mount

ing  screws  underneath.

5. Using  a  suitable  tool  or  with  the  aid  of  the  coupling,  align  the  shaft  of  the  sensor

box  so  that  the  shaft  of  the  sensor  box,  the  coupling  and  the  shaft  of  the
quarter−turn  actuator  all  intermesh  in  the  desired  way  (see  example  in  Fig.9).

1

Quarter−turn  actuator 
(here  DFPB)

2

Coupling  for  force
transmission

3

Shaft  of  the  sensor  box

4

Sensor  box  SRAP
(view  from  below)

Fig.9

1

2

3

2

4

6. Position  the  sensor  box  on  the  quarter−turn  actuator  so  that  the  two  shafts  en

gage.  If  necessary,  use  appropriate  mechanical  adapter  bridges  and  couplings
(

è

  catalogue  www.festo.com/catalogue).

7. Tighten  the  four  mounting  screws  (Fig.1 

8

)    torque  max.  5  Nm.

7.2 Adjusting  the  visual  position  indicator

You  may  need  to  adapt  the  visual  three−dimensional  position  indicator  to  the  re
quirements  of  your  valve.  To  do  so,  you  must  remove  the  indicator  ring  and  disas
semble  the  sections  of  the  position  indicator.  You  can  then  put  the  sections  back
together  according  to  your  requirements.

Removing  the  indicator  ring

1. Turn  the  indicator  ring  until  the  bottom  edge  of  the  indicator  ring  and  the  bottom

edge  of  the  plastic  cap  are  flush.

2. Pivot  the  indicator  ring  around  90°  (see  Fig.10).
3. You  can  now  remove  the  indicator  ring  from  the  cover  of  the  sensor  box.

Fig.10:  Removing  the  indicator  ring

1

2

3

Assembling  the  sections

Caution

If  handled  improperly,  the  clips  on  the  position  indicator  sections  could  break
off.
· Take  care  to  clip  the  sections  together  without  breaking  off  the  fastening

clips.

1. Clip  the  sections  of  the  visual  position  indicator  together  in  such  a  way  that  the

open  paths  of  the  valve  are  displayed.

Fig.11:  Clipping  the  sections  of  the  indicator  ring  together

Be  sure  to  make  the  centre  piece  (position  pointer)  and  the  indicator  ring  each
from  sections  of  the  same  colour.  One  section  is  included  separately.

Fig.12:  Construction  of  the  position  indicator    examples

Mounting  the  position  indicator

1. Insert  the  indicator  ring  back  into  the  sensor  box  cover,  by  reversing  the  steps

for  removal  (

è

  also  Fig.10).

2. Push  the  centre  piece  (position  pointer)  of  the  position  indicator  back  onto  the

shaft  of  the  sensor  box.  Make  sure  the  alignment  is  correct.

Before  you  put  the  cover  of  the  sensor  box  back  in  place,  you  must  carry  out  the
electrical  installation  (

è

  section  7.3).

After  that  you  can  put  the  cover  of  the  sensor  box  back  in  place    torque 
max. 5 Nm.

7.3 Electrical  installation

Warning

Use  only  power  units  which  guarantee  reliable  electrical  isolation  of  the  opera
ting  voltage  as  per  IEC/DIN  EN60204−1.  Obser ve  also  the  general  requirements
for  PELV  power  circuits  as  per  IEC/DIN  EN  60204−1.

Caution

Installation  errors  can  damage  the  electronics  or  cause  faults.
 Use  an  electrical  connecting  cable  with  a  nominal  outside  diameter  of  5  to

13mm.

 Make  sure  that  the  length  of  the  signal  cable  does  not  exceed  the  permissible

length  of  30  m.

 To  transmit  analogue  signals,  use  only  screened  cables  with  twisted  pairs.

Attach  the  cable  screening  at  one  end  to  the  higher−level  system.

 Connect  the  earth  connection  (

è

  Fig.1 

aJ

)  with  low  impedance  (short  cable

with  large  cross−sectional  area)  to  the  earth  potential.

Caution

The  sensor  box  contains  electrostatically  sensitive  devices.  The  internal  electro
nic  components  may  be  damaged  if  they  are  not  handled  correctly.
· Observe  the  handling  specifications  for  electrostatically  sensitive  devices.
· Discharge  yourself  electrostatically  before  fitting  or  removing  components  in

order  to  protect  the  components  against  discharges  of  static  electricity.

The  electrical  connection  terminals  are  built  into  the  device.  The  device  must  be
opened  for  electrical  installation.  To  dismantle,  see  the  steps  in  section  7.1.

1. If  not  already  done,  open  the  cover  and  release  the  terminal  strip,  as  described

in  section  7.1.

2. Route  the  electric  cable  through  the  cable  connector.
3. Use  wire  end  sleeves  suitable  for  the  connection  and  wire  the  terminal  strip

according  to  the  pin  allocation    cable  cross  section  max.2.5  mm³;  torque  max.
0.6  Nm.

Reviews: