Fitting and removing the modules
CAUTION
Modules can be damaged by incorrect handling.
•
Do not touch any of the components.
•
Observe the regulations for handling components which
are affected by electrostatic charges.
•
Discharge yourself electrostatically before fitting or
removing modules, in order to protect the components
against discharges of static electricity.
Seal unused locations with blind front plates (type SPC200-PB).
This complies with protection class IP 20. Depending on the
number of locations available, up to 3 stepping motor indexer
modules can be fitted into a rack.
PLEASE NOTE
If you are using an operating panel, fit the stepping motor in-
dexer module in the rack with at least one free slot between
it and the diagnostic module type SPC200-MMI-DIAG.
Removing the modules
1. Switch off the operating voltage and the compressed air
supply.
2. Loosen and remove the connecting cable on the front of the
module.
3. Unlock both safety catches by pushing them aside (see
following diagram).
4. Grip the module by the front plate and pull it out.
5. Any unused slots should be sealed with blind plates.
E
n
g
lis
h
SPC200-SMX-1