Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 59
Vision Sensor Manual
Fig. 49: Vision Sensor Configuration Studio, Load / save job
4.6.1.3 Parameters for image acquisition
The basic parameters for image acquisition are determined in the tab Image acquisition.
Next topic:
Preprocessing, Filter for image improvement. (Page 61)
Set image sharpness with the focus setting screw on the back of the SBS .
Parameters
Functions and setting possibilities
Resolution
Standard resolution is VGA (640x480), but a lower resolution (QVGA) can be
selected with time-critical applications or for compatibility reasons.
Available resolutions:
R3B: WVGA (736x480), VGA (640x480), QVGA (320x240), QQVGA (160x120)
R3BC: WVGA (736x480), VGA (640x480), QVGA (320x240)
R2B: XGA (1280x1024), VGA (640x480), QVGA (320x240)
R2BC: XGA (1280x1024), VGA (640x480)
When the resolution is altered, all the detectors previously defined are deleted!
Zoom (R2B only)
Via the Zoom function different fields of view / image zones can be selected
Dynamic
Optimization of characteristics of image capturing: "Linear" means linear response
curve(behaves like SBS -products with no dynamic image capturing), "High" means
better graduation in bright areas of the image (avoids override).
Trigger mode
Select trigger mode (triggered or free run).
In case of triggered mode trigger can be done by hardware-trigger (Pin 03 WH) or
over one of the data interfaces.
In free run the SBS continuously captures images and processes evaluations.
Shutter speed
Parameter for control of image brightness.
Image brightness preferably should be set with “Shutter speed”, only in case that
it´s not possible to achieve the required image brightness this way use the slider
Summary of Contents for SBSC-EN
Page 1: ......